E 17 - Input sensor disconnected
Error description
This error is displayed when the inlet PT100 sensor is disconnected.
Error analysis
2. Defective
PT100 interface
on PCB.
Measure the resistance on
thePT100 sensor between
P18-4 and P18-3 on PCB.
Is the resistance 110 k
Ω
at 20°C (68°F)?
Replace PT100
sensor or harness.
Go to step 2.
NO
YES
1. Defective
PT100 sensor/
harness?
YES
Replace the PCB.
Resetting