INSTALLATION INSTRUCTIONS | SmART LINE BOILINg PAN
EN | 10-2018
DOC N° ST0 9183-02
25
12.5
Boiling pans with option ice water cooling SV6I, SP6I
12.5.1
Single Stand 50L, 80L and 100L
1
Fixtures: PNC 928029
2
Alternative direction of drainage
12.5.2
Right column 50L, 80L and 100L
Connections:
A
Hot water: DN15 (g1/2”) internal thread
B
Cold water: DN20 (g3/4”) male thread
C
Electrical cable
D
Shut-off valves (not supplied)
E
Joints between electrical cables and pipes are
sealed
F
min. cable length 0.75 m
G
Front edge of frame
H
Steam connection, 110-170 kPa (1.1-1.7 bar)
Steam-heated pans: DN20 (g3/4”) Internal thread
I
Condensation connection (Steam-heated pans):
DN20 (g3/4”) Internal thread
In case of alternative connection from the rear:
a
Hot water: DN15 (g1/2”) internal thread
b
Cold water: DN20 (g3/4”) male thread
c
Electrical cable
50L
80L
100L
r
595
763
763
K
400
600
600
L
700
900
900
m
565
710
710
N
1245
1375
1420
T
250
305
305
U
135
190
190
Fig. 10
Fig. 11
Summary of Contents for Smart