INSTALLATION INSTRUCTIONS | SmART LINE BOILINg PAN
22
DOC N° ST0 9183-02
EN | 10-2018
12.3
Frames and fixtures
Foundation or mounting frames and fixtures are
supplied disassembled. These should be as-
sembled according to the following instructions.
NOTE
Please follow these instructions
• Check that the dimensions of the supplied
frames and number marking on the various
fixtures agree with the information in this in-
stallation instruction.
• Check that: measure
r
, between the wall and
the mounting frames, is correct to an accur-
acy of +/- 2 mm. (See Fig. 4, 7 and 10)
Frames
D
/
E
and fixtures
B
are screwed together
with the enclosed screws m6S 12x20 (see Fig.
4A-B).
Angle between fixtures and frames is 90° (check
with set square), (see Fig. 3).
r
: For measure see subsequent pages
G
: Front edge of frame.
model
foundation frame
PNC
mounting frame
PNC
Left Sm6B,
Sm6V, Sm6P
928031
928034
Left SV6I, SP6I
928032
928035
Right 50-100L
928032
928035
Right 150-300L
928033
928036
12.3.1
Foundation frames
The foundation frames
D
are cast:
• So that level A is 5-10 mm above the highest
point of the finished floor
• Horizontal in all directions
• The last part of the frame must be filled with
compound or similar up to Level
A
• Expander bolt
C
, chemical anchor or equival-
ent m10, (not supplied)
• min. extraction force 500 kp = 4900 N
12.3.2
mounting frames
The mounting frames
E
are secured:
• With expander bolt
C
, chemical anchor or
equivalent m 10, (not supplied)
min. extraction force 500 kp = 4900 N
• NOTE: The frames are at the same level
• Horizontal in all directions
• The frame must be filled with compound or
similar up to Level
A
Fig. 3
Fig. 4A
Fig. 4B
Summary of Contents for Smart