7
ENGLISH
Install a disconnecting switch with a capacity at
least equal to that given in the technical data table,
a 30mA residual current circuit breaker and an
overcurrent device (magnetothermal cut-out with
manual reset or fuse) between the appliance and
the mains power outlet.
The chosen device must be lockable in the open
position in case of maintenance.
RATING PLATE
The rating plate contains identification and technical
data and is located on the right-hand side panel of the
appliance (Fig. 5).
Fig. 5
B1
WATER CONNECTION
•
Position the dishwasher and level the appliance by
turning the relative height-adjustable feet (Fig. 5).
•
Connect the appliance water supply pipe “A”
(Fig. 4) to the mains, fitting a cut-off cock, the filter
provided and a pressure gauge between the appli-
ance and the mains (Fig. 6).
Fig. 6
•
Check that the
dynamic
water supply
pressure
,
measured between the appliance and the main, is
between 200 and 300 kPa
for machines with pres-
sure boiler and
between 50 and 700 kPa
for
machines with atmospheric boiler (test while dish-
washer tank or boiler is filling with water).
If the
pressure is too high, fit a suitable pressure
reducer on the inlet pipe.
-
On the model with free-fall drainage:
connect the waste outlet pipe “C” (Fig. 4) to the main
drain pipe, fitting a trap, or place the outlet pipe over an
“S” trap set into the floor.
-
On the model with drain pump:
position the outlet pipe at a height anywhere between
750 and 1000 mm from the floor.
Check that about 4 litres of water flow out of the outlet
pipe during the rinse cycle.
B2
ELECTRICAL CONNECTION
Fig. 7
•
Before carrying out the electrical connection, check
that the voltage and frequency on the appliance rat-
ing plate correspond to those of the mains electric-
ity supply.
•
The earth wire at the terminal end must be longer
(max. 20 mm) than the phase wires.
•
Connect the earth wire of the power supply cable to
an efficient earth clamp. The appliance must also
be included in a unipotential system, the connec-
tion being made through the screw “Q” (Fig. 4)
marked with the symbol “
”. The unipotential wire
must have a cross section of 10 mm
2
.
B INSTRUCTIONS FOR THE INSTALLER/MAINTENANCE PERSON
MOVING THE MACHINE WITH THE
DOOR OPEN OR GRIPPING IT
WITHOUT TAKING INTO ACCOUNT ITS
ACTUAL WEIGHT OR CENTRE OF
GRAVITY IS EXPRESSLY FORBIDDEN
(DANGER OF TIPPING OVER).
Model LS7E
PNC 9CGX 500100 05 Ser.N .523000001
AC 400V 3N 50Hz
Power Boiler 16500w
Power Tank 7500w
Power Max 26800w
Made in EU
Model LS7E
PNC 9CGX500100 05
Ser.N .523000001
!
CAUTION
THE EARTH AND ELECTRICAL CON-
NECTIONS SHOULD BE IN COMPLI-
ANCE WITH NATIONAL REGULATIONS.
AC
4
00..
..
1
11
10
9
8
7
6
5
4
3
2
12
!
Summary of Contents for LU7
Page 16: ...18 ...