5
ENGLISH
A4
TECHNICAL DATA
Standard cycle time may vary should the inlet water temperature and/or the boiler heating elements be different from
that indicated above.
MODEL
LU7 / LU700 / WTU40
Supply voltage:
V
400...415- 3N~
- convertible to
V
220...240- 3~
- single-phase version
V
220...240 1N~
Frequency
Hz
50 or 60
Max. power input
kW
9.9 / 12.1 (*)
Boiler heating elements
kW
9
Tank heating elements
kW
2.2
Water supply press. for atmospheric boiler versions
kPa [bar]
50...700 [0,5...7]
Water supply press. for pressure boiler versions
kPa [bar]
200...300 [2...3]
Water supply temperature
°C
50
Water supply hardness for models without incorporated
continuous water softener
°f/°d/°e
14/8/10 max
Electric conductivity of water for models without incorporated
continuous water softener
μ
S/cm
< 400
Water supply hardness for models with incorporated water
softener
°f/°d/°e
40/22,4/28 max
Concentration of chlorides in water
ppm
< 20
Rinse cycle water consumption
l
3.8
Boiler capacity
l
12
Tank capacity
l
42
Standard cycle time with water supply at 50°C
sec.
55-90-300
Legal noise level Leq
dB(A)
<68
Protection rating
IPX4
Net weight for models without incorporated continuous water
softener
kg
97
Net weight for models with incorporated continuous water
softener
kg
100
Power supply cable
H07RN-F
Supply cord diameter (min. - max. value)
mm
18 - 25
(*) = If activated by software, coincidence of tank and boiler heating elements.
Table 1
400..415 V 3N
220...240 V 3
220…240 V 1N
C
S
C
S
C
S
9.9 kW
5X2,5
20 A 3P+N
4X6
32 A 3P
3X10
60 A 1P+N
12.1 kW
5X4
32 A 3P+N
4X10
50 A 3P
3X10
70 A 1P+N
C = Power supply cable
S = On/Off switch
Table 2