Clause-Remedy
1.
Erratic control thermostat, or setting too cold -
replace are reset to normal position.
2.
Freezer exposed to unusual heat - relocate freezer.
3.
Abnormally high room temperature - advised
customer.
4.
Low pumping capacity compressor - replaced
compressor.
5.
Lid gasket not ceiling - adjust or replace necessary
parts.
6.
System undercharged - check for leaks.
8.
Interior light stays on - check lid switch.
9.
Non-condensables in system - replaced filter drier,
evacuate, and recharge.
10. Capillary tube kinked or partially restricted - replace
heat exchanger.
11. Filter drier, partially restricted - replace filter drier.
12. Excessive service load - advise customer.
13. Restricted airflow over condenser - ensure condenser
has unobstructed airflow.
1.
Tubing vibrates - adjust tubing.
2.
Internal compressor noise - replaced compressor.
3.
Compressor vibrating on cabinet frame - just
compressor.
4.
Loose parts - check shelving, kick plate, and
defrost drain pan.
5.
Compressor operating at high head pressure due to
restricted airflow around freezer - ensure freezer is
installed properly.
Complaint.
Compressor Runs Too Much or 100%.
Noisy.