![Electrolux FROST- FREE Service Manual Download Page 21](http://html.mh-extra.com/html/electrolux/frost-free/frost-free_service-manual_94079021.webp)
21
3. Defrost Timer Motor Circuit.
The defrost timer motor circuit is made up of the cold
control and the defrost timer motor. Whenever the
cold control contacts are closed. Power is applied
to the defrost timer motor. This means that the
defrost timer motor only runs whenever the cold
control contacts are closed.
4. Freezer Interior Light.
The freezer Interior light circuit is made up of a spring
loaded lid switch and a (25) Watt light bulb.
Whenever the lid is raised the contacts of the spring
loaded switch closes, applying power to the
light bulb.
5. Power On Light.
The power on light is connected between line and
neutral and glows anytime power is applied to the
freezer.
L1
N
COLD
CONTROL
DEFROST
MOTOR
L1
N
INTERIOR
LIGHT
LID SWITCH
L1
N
POWER ON