0209
5
8
01106073
Page
Notice
Date
OPERATING
HANDBOOK
"Com. Error Folder" message
The screen will alternately display this fl ashing
message and the service screen.
This message means that there is a communication
failure between the control panel and the folding
programmable logic controller.
•
Check the link between the control panel and the
programmable logic controller.
•
Check the setting of the programmable logic
controller.
• In
the
Set 2
menu of the service program check
the confi guration for the control panel. The
MANU
parameter should be selected.
If the fault remains, consult your after-sales service.
Error of communication with the folding option
"Folder Error 002" message
The screen will alternately display this fl ashing
message and the service screen.
This message followed by a number means a failure
in the folder running.
Switch off then switch back on the power supply using
the main switch. If the fault remains, consult your
after-sales service.
Error of the folder running
The following three screens will only appear if you have a machine with a folding option and ma-
nual fold adjustment.
Error
Com. Error Folder
Error
Folder Error 002
Error
Reception not ready
Message: "Problem - tank positioning error".
The screen displays the following fl ashing message,
alternating with the service screen.
This message shows that the reception tank on the
machine is not in the correct position for the folding
option that you have chosen:
• Raised to use the machine without folding (folding
mode:
WITHOUT
).
• Lowered to use the machine with folding (folding
mode:
FIX
or
PLIVIT
).
Positioning fault with the reception tank
5. Operating incidents