Tech Sheet – Laundry Center FFL(E/G)3911/4033
GD000006035-B
Page 9 of 11
Alarm
Code
Alarm
Description
Fault
Condition
Possible
Fault
Machine
Action/Status
Action to
Clear
EBE
(EHE)
Motor Control Board
Relay error
Incongruence between safeties relay sensing
and Motor Control Board relay status
Motor Control Board Relay defective
Wiring or main board
Safety drain
Cycle abort
RESET
EBF
(EHF)
Motor Control Board relay
sensing error
Input voltage value on microprocessor
always to 0V or to 5V
Main board
Safety drain
Cycle abort
RESET
EC6
Clutch Alarm
Clutch positioning timeout to reach or failure to
stay in desired position
Clutch mechanism failure
Main board defective
Wiring/connection problem
Cycle abort
EC7 Clutch triac sensing Failure
The sensing of the clutch triac is out of the
limits
Clutch mechanism failure
Main board
Wiring/connection problem
Cycle abort
EF2
Foam warning
Suds lock detected during spin phase at the end
of the washing phase
Incorrect or excessive detergent
Drain pipe blocked or clogged
Alarm is silent and the cycle
is extended
EF6
Safety reset
Main board microcontroller damaged
Main Board
None