Tech Sheet – Laundry Center FFL(E/G)3911/4033
GD000006035-B
Page 2 of 11
3 Diagnostic Program Definition
1. Cycle Selector knob in the Normal position 12 o’clock is the zero position where the switches can be
checked.
2. Turn the Cycle Selector knob (1) click clockwise from Normal position.
•
The lid lock will activate and the hot water solenoid will activate and hot water shall enter the
tub.
•
Note: Clutch actuator starts rotating to find the "disengaged" position, when there it stops.
3. Turn the Cycle Selector knob (2) clicks clockwise from Normal position.
•
The cold water solenoid will activate and cold water shall enter the tub.
•
Note: Clutch actuator rotates to find the "disengaged" position, when there it stops.
4. Turn the Cycle Selector knob (3) clicks clockwise from Normal position.
•
The lid lock will deactivate and the lid can be opened.
5. Turn the Cycle Selector knob (4) clicks clockwise from Normal position.
•
The lid lock will activate and both the hot and cold water solenoids will turn on and fill up to a
certain level. After the Pressure Sensor has been satisfied, agitation will begin.
•
If softener option is available on the machine, then the softener solenoid will also activate and
the softener compartment will be filling up and siphoning cold water at the same time.
6. Turn the Cycle Selector knob (5) clicks clockwise from Normal position.
•
The drum will stop and the drain pump will activate, draining out any water in the tub.
•
After draining the clutch actuator will start moving continuously, for about 1 minute
7. Turn the Cycle Selector knob (6) clicks clockwise from Normal position.
•
The Drain Pump turns on until no water is detected on the sensor, the clutch actuator rotates
to find the "engaged" position
•
The Drain Pump turns off just before the drum starts its rotation to a high speed spin.
8. Turn the Cycle Selector knob (7) clicks clockwise from Normal position.
•
The control will signal the last 3 error codes. Press the cycle Selector to scroll through them.
(See the part about reading error codes)
•
Press and hold the selector knob for at least 5 seconds in this position to clear the alarm
history.
4 Exiting Diagnostics Mode
Any one of the following methods may be used to exit DM:
•
Disconnect power and wait 5-8 seconds then reconnect power.
•
Press and hold the knob for at least 5 seconds in selector position modes 1 to 6 CW.
•
The machine exits diagnostic mode after 15 minutes of no UI activity.