16
5. Pump and motor assembly is secured in place
using four retainers that will turn into sump to
release from tub. Lift assembly into tub.
6. Remove wires from motor.
Precision Direct Wash System
1. Disconnect the dishwasher from electrical supply
2. Remove spray arm, spray arm support, and filters
from inside of tub
3. Remove outer door panel and kick plate to gain
access to the underside of the dishwasher.
4. Disconnect wires from both wash motor and drain
pump, then remove the clamp from the delivery
tube, this clamp can be accessed going back the
right side of the sump. The clamp on the delivery
tube has a 1/4 inch head. Carefully push delivery
tube off rear port of the sump.
5. Pump and motor assembly is secured in place
using four retainers that will turn into sump to
release from tub. Push sump into tub, then by
rotating to the right will aid in clearing wash pump
and drain pump as sump is lifted out
Lift sump to the 2:00 position to remove
4. Disconnect delivery tube and sump drain hose.
Sump
retainer
Delivery
tube
and clamp
Hose from sump to
drain pump with
clamps
Wash pump
and motor
Delivdery tube
Lock Retainers
Front
Rear
Right
Left
Drain pump
Remove motor from sump.
Removing mounting bracket
Forcing motor from sump
1. Remove sump from tub
2. Remove volute cover and check ball
3. Turn sump over and remove motor mounting
bracket (2 screws)
4. Lift bracket from sump.
5. Return sump to up right position.
6. Place end of a flat blade screwdriver in front of
wash impeller and force motor out rear of sump.
Summary of Contents for FDB1050RE 2005
Page 33: ...B 1 ...
Page 35: ...B 3 ...