![Electrolux FDB1050RE 2005 Service Manual Download Page 16](http://html.mh-extra.com/html/electrolux/fdb1050re-2005/fdb1050re-2005_service-manual_2381822016.webp)
15
4. To install tube start by placing tube in top of tub
and installing shower nozzle loosely.
5. Place center opening in tub and installing screw
make sure tube is snug in tub grommet before
installing screw
6. Install tube onto sump and tighten clamp.
7. Return and reseat the top of the tube and tighten
shower nozzle.
PUMP AND MOTOR ASSEMBLY
Precision Wash
1. Disconnect the dishwasher from electrical supply
2. Remove spray arm, spray arm support, and filters from
inside of tub.
3. Remove outer door panel and kick plate to gain access
to underside of dishwasher.
DELIVERY TUBE.
Precision Wash
1. With dishwasher removed from under counter top
unscrew and remove nozzle in top of tub holding
tube in place. Nozzle unscrews counter clockwise.
2. Loosen clamp on sump and remove tube.
1. With dishwasher removed from under counter top
unscrew and remove shower nozzle in top of tub.
Nozzle unscrews counter clockwise.
3. Insert small
screwdriver
into top hole of
pump mount
on front of
sump, push
down on screw
driver to
release top
mounting hook
pull top of
pump back and hold.
4. Insert screwdriver
this timer in lower
hole in pump
mount, push down
and pull back on
pump will release
pump from sump.
Precision Direct Wash System
5. Pump can now be
removed.
NOTE:
To remove Delivery tube, from either the
Precision or Precision Direct Wash system models,
the dishwasher will need to be removed from under
counter top.
2. Remove mounting screw in back of tub.
3. Remove clamp from sump end and remove tube.
Summary of Contents for FDB1050RE 2005
Page 33: ...B 1 ...