18
2 Take off wire cable clamp. Connect and screw
the power connection cable onto the terminal
EORFNIROORZLQJFRUUHVSRQGLQJLGHQWL¿FDWLRQ
numbers and colors on the terminal blocks of
indoor and outdoor units.
3 To prevent water from entering, make a trap
³8´LQWKHFRQQHFWLRQZLUHVVHHSDJH
Wrap wires that are not connected with
insulating tape so that they do not touch any
electrical or metal parts.
Fix the power connection wires with wire
clamps.
6 Reinstall the handle.
Blue
Black
Brown
Earthing wire
(Yellow-Green)
Cable clamp
To Indoor Unit
$IWHUFRQ¿UPLQJWKHDERYHFRQGLWLRQV
prepare the wiring as follows:
The screws which fasten the wiring to
the terminal block may come loose from
vibrations during transportation.
Check and make sure all screws are well
¿[HG2WKHUZLVHLWFRXOGFDXVHEXUQRXW
of the wires.
%HVXUHWKHFLUFXLWFDSDFLW\LVVXI¿FLHQW
Ensure the starting voltage is maintained
at over 90% of the rated voltage marked
on the nameplate.
&RQ¿UPWKDWWKHFDEOHWKLFNQHVVLV
DVVSHFL¿HGLQWKHSRZHUVRXUFH
VSHFL¿FDWLRQ
Always install a Residual Current Device
(RCD) in wet or moist area.
The following may be caused by voltage
drop: Vibration of a contactor, which will
damage the contact point, fuse blowing,
disturbance of the normal function of the
overload.
The means for disconnection from a
power supply shall be incorporated in the
¿[HGZLULQJDQGKDYHDQDLUJDSFRQWDFW
separation of at least 3mm in each active
(phase) conductor.
Step 10: Checking the Drainage
A. Open and lift the indoor unit front panel.
Hold the lower part of the left and right sides
of the panel, pull it against you and lift it until a
click is heard.
caution
caution
B. Check the drainage
Carefully pour a glass of water on the
evaporator.
(QVXUHWKHZDWHUÀRZVWKURXJKWKHGUDLQ
hose of the indoor unit without any leakage
and goes out the drain exit.