1
2
1
Unit
2
Hook
4. Coil tape around the drain hose together
with the pipes and electrical cable.
5. Hook the unit onto the mounting plate.
Connecting the electrical cable to the
indoor unit
1. Process the end of the electrical cable for
the indoor side.
– Use a copper cable. (Cross-section
area 2mm² or more)
– Use a cable which is not lighter than
polychloroprene sheathed flexible cord
(design 245 IEC 57).
8mm
40mm
2. Open the open panel by about 70°.
3. Connect the electrical cable.
– Be very careful not to confuse the ter-
minal connections. Wrong cabling may
damage the internal control circuit.
– The markings on the indoor unit’s ter-
minal board must match with those of
the outdoor unit.
1
N
2
7
8
1
2
3
1
Earth wire
2
Electrical cable
3
Terminal board
4. Fix the cable with the accompanying cord
holder and the short screw.
5. Close the open panel.
Connecting the drain hose
Indoor unit
1. Connect a drain hose.
2. Tape over the connecting part.
1
ø 18mm
1
Drain hose
8
electrolux
Summary of Contents for EXH09HX