4. After 5~10 minutes, fully close the 2-way
valve by turning the hexagon socket
screw key clockwise.
5. After 2~3 minutes, immediately close the
3-way valve fully.
6. Stop the test run operation.
7. Replace both valve shaft caps tightly.
8. Disconnect both refrigerant pipes.
• Do not perform the pump down when at
heating mode. The refrigerant will not be
collected.
Connecting the electrical cable to the
outdoor unit
1. Process the end of the electrical cable for
the outdoor unit.
8mm
40mm
2. Remove the control box cover.
3. Remove the cable holder and connect
the cable.
Be sure that the terminal connections are
as specified.
4. Fix the electrical cable sheath with the
cable holder and the screw.
5. Double-check that the cable is securely
in place.
6. Place the control box cover back in the
reverse order.
1
2
3
4
5
6
2
N 1
1
Earth wire
2
Terminal board
3
Cable holder
4
Electrical cable
5
Control box cover
6
Screw
Caution!
• Use the specified electrical cable.
Make sure the cable is secured in
place and that the terminals are free of
any excess force from the cable. Oth-
erwise overheating or fire may result.
• Dress the cable so that the control box
cover, the cord holder and cable hold-
er are not loose. Double-check that
the cover is tight in position. Other-
wise overheating, fire or electric shock
may result.
• Be sure to put the cable leads deep
into the terminal board and tighten up
the screws. Poor contact can cause
overheating or fire, or malfunction.
Power cabling
Prepare a dedicated power supply circuit.
For the connections, see below.
Supply power
220-240V, single-phase
Circuit breaker
10A (EXH09HX)
15A (EXH12HX)
12
electrolux