SOI/DT 2004-11 dmm
599 36 75-68
22/67
7.5
Synthetics programmes: cold – 30 – 40 – 50 – 60° (without options)
Motor Movement
CYCLE
N.° PHASE
Description
Drain
pump
Recirc.
Pump
Deterg.
Disp
Rpm
Movem.
Pause
60 50 40 30 *
1 Calibration
Level
ON OFF
No
movem
Drain
2 Flow
calibration
Level
OFF
OFF
PW
No movem
Water fill
3
Maintenance water softener
Time
OFF
OFF
PW
55
4
12
1 min.
4
Water fill
Level
OFF
OFF
PW
No movem
COT_FIRST_PW_LEV
5
Maintenance & Refill
Time
OFF
ON (35/15)
PW
55
4
12
4 min.
COT_FIRST_PW_LEV
6
Heating
Temperature
OFF
ON (35/15)
PW
55
4
12
Heating up to 30°
20°
7
Maintenance
Time
OFF
ON (35/15)
PW
55
4
12
10 min.
8 Drain
Time
ON
OFF
No movem
Empty Elect.+ 14 sec.
9
PREWASH
Spin
Time
ON
OFF
IMP C0
4,5 min. with AS control
10 Calibration
Level
ON OFF
No movem
Drain
11 Flow
calibration
Level
OFF OFF
PW No movem
Water fill
12
Maintenance water softener
Time
OFF
OFF
PW
55
4
15
1 min.
13
Water fill
Level
OFF
OFF
W
No movem
SYN_FIRST_W_LEV
14
Maintenance & Refill
Time
OFF
ON (35/15)
W
55
8
8
3 min.
SYN_SEC_NW_LEV
15
Heating
Temperature OFF ON
(35/15) W 55 10 3 60° 50° 40° 30° 20°
16 Maintenance
Time
OFF
ON (35/15)
W
55
10
3
10 min. 10 min. 10 min. 10 min.
20° ref
10 min.
17 Heating
Time
OFF ON
(35/15) W 55 10 3 60° 50° 40° 30°
18 Maintenance
Time
OFF
OFF
W
55
10
3
15 min. 15 min. 15 min. 15 min.
19
Maintenance
Temperature
OFF
ON
(35/15)
W
55
10
3
15
min.
20 Cooling
Time
OFF
OFF
W
55
8
8
Qc (4 Litres)
21 Maintenance
Time
OFF
ON (35/15)
W
55
4
12
2 min.
22 Drain
Time
ON
OFF
No movem
Empty Elect.+ 14 sec.
23 Drain
Time
ON OFF
55
4
12
1
min.
24
WASH
Wait Time
ON
OFF
No movem
6 sec.
(The data are indicative)
PW = Prewash BL = Bleach
SF = Softener W = Wash AS = Anti-foam