SOI/DT 2005-01 dmm
599 36 82-59
54/67
12.3.2 Programme selector
In the table are indicated the closures between the contact C6 (common) and the other contacts (C
1−
C5) of
the programme selector in the different positions and the corresponding codification. The code is displayed
only in the appliances with display
.
Selector position
Closure of selector contacts
(C6 is the common)
Display
code
Type 24
positions
Type 12 positions
(C1 is not
featured)
C1 C2 C3 C4 C5
1 - Cancel
1 - Cancel
0 1 1 1 1
1 E
2 2
0 1 0 0 1
0 6
3 -
0 1 1 0 0
1 4
4 3
0 1 0 1 0
0 C
5 -
0 1 1 1 0
1 C
6 4
0 0 0 1 1
0 A
7 -
1 0 0 0 0
0 1
8 -
1 0 0 0 1
0 3
9 -
1 0 0 1 0
0 9
10 5
0 1 0 1 1
0 E
11 6
0 0 1 0 1
1 2
12 -
1 0 0 1 1
0 b
13 -
1 0 1 0 0
1 1
14 7
0 0 1 1 0
1 8
15 -
1 0 1 0 1
1 3
16 8
0 0 1 1 1
1 A
17 -
1 0 1 1 0
1 9
18 -
1 0 1 1 1
1 b
19 -
1 1 0 0 0
0 5
20 9
0 1 1 0 1
1 6
21 -
0 0 0 0 1
0 2
22 10
0 1 0 0 0
0 4
23 11
0 0 0 1 0
0 8
24 12
0 0 1 0 0
1 0
Selector position
Closure of selector contacts
(C6 is the common)
Display
code
Type 16
Positions
(C1 is not featured)
C1
C2 C3 C4 C5
1 - Cancel
0 1 1 1 1
1 F
2
0 1 0 0 1
0 7
3
0 1 1 0 0
1 5
4
0 1 0 1 0
0 D
5
0 0 0 1 1
0 B
6
0 1 0 1 1
0 F
7
0 0 1 0 1
1 3
8
0 0 1 1 0
1 9
9
0 0 1 1 1
1 B
10
0 1 1 0 1
1 7
11
0 1 1 1 0
1 D
12
0 0 0 0 0
0 1
13
0 1 0 0 0
0 5
14
0 0 0 1 0
0 9
15
0 0 0 0 1
0 3
16
0 0 1 0 0
1 1
1= This code is shown on the display