SOI/DT 2005-01 dmm
599 36 82-59
59/67
Alarm
Description
Possible fault
Action/machine status
Reset
E36
Sensing circuit on anti-boiling pressure switch 1
defective
Main board defective.
Cycle stops with door locked
OFF/reset
E37
Sensing circuit on anti-boiling pressure switch 2
defective
Main board defective.
Cycle stops with door locked
OFF/reset
E38
Internal pressure takeoff is clogged (water level
does not change for at least 30 sec. of drum
rotation).
Water circuit on pressure switches;
Pressure switches;
Motor belt broken;
Heating phase is skipped
---
E39
Defective HV sensing on anti-overflow system
Main board defective.
Cycle stops with door locked
OFF/reset
E3A
Faulty sensing by heating resistance relay
Main board defective.
Cycle stops with door locked
OFF/reset
E41
Door unlocked
Door lock unit defective; Wiring defective;
Main board defective.
Cycle is paused
Start
E42
Problems closing the door
Door lock unit defective; Wiring defective;
Main board defective
Cycle is paused
Start
E43
Defective triac supplying power to door delay
system
Door lock unit defective; Wiring defective;
Main board defective.
(Emergency drain procedure) Cycle
stops
OFF/reset
E44
Defective sensing by door delay system
Main board defective.
(Emergency drain procedure) Cycle
stops
OFF/reset
E45
Defective sensing by triac on door delay system
Main board defective.
(Emergency drain procedure) Cycle
stops
OFF/reset
E51
Motor power supply triac short-circuited
PCB faulty; current leakage from motor or from wiring.
Cycle blocked, door locked (after 5
attempts)
OFF/reset
E52
No signal from motor tachometric generator
Motor faulty; wiring faulty; PCB faulty
Cycle blocked, door locked (after 5
attempts)
OFF/reset
E53
Motor triac sensing circuit faulty
PCB faulty.
Cycle blocked, door locked
OFF/reset
E54
Motor relay contacts sticking
PCB faulty; current leakage from motor or from wiring
Cycle blocked, door locked (after 5
attempts)
OFF/reset
E61
Insufficient heating during washing
NTC sensor faulty; heating element faulty; wiring faulty; PCB faulty. The heating phase is skipped
---
E62
Overheating during washing
NTC sensor faulty; heating element faulty; wiring faulty; PCB faulty.
Safety drain cycle – Cycle stopped
with door open
OFF/reset
E66
Heating element power relay faulty
PCB faulty; current leakage from heating element to ground.
Safety drain cycle – Cycle stopped
with door open
OFF/reset
E71
NTC sensor for wash cycle defective
Defective NTC sensor; Wiring defective;
Main board defective.
Heating is skipped
Start
E72
Fault in NTC sensor on drying condenser (voltage
out of range = short-circuit, open circuit)
Drying NTC sensor (condenser) defective; wiring defective; main
circuit board defective.
Heating is skipped
Start
E73
Fault in NTC sensor on drying duct (voltage out of
range = short-circuit, open circuit)
Drying NTC sensor (duct) defective; wiring defective; main circuit
board defective.
Heating is skipped
Start
E74
NTC sensor for wash cycle improperly positioned
NTC sensor improperly positioned; Defective NTC sensor; Wiring
defective; Main board defective.
Heating is skipped
Start
E82
Error in selector reset position
PCB faulty (Wrong configuration data). Selector, wiring
---
OFF/reset
E83
Error in reading selector
PCB faulty (Wrong configuration data). Selector, wiring
Cycle cancelled
---