E43
E43: Problems with the triac which actions the door interlock
E43
Detach the connectors and
effect measurement on the
component
(fig. 9):
- across connectors 3 and 5
the circuit must NOT be
open (the resistive value
should be measurable).
- across connectors 4 and 5,
the circuit must be OPEN
(the numbers are printed on
the component).
Is the door safety interlock
OK?
To check the wiring, (with the door
open), measure the following
wiring connectors
(fig. 4)
:
-between wires J1-3 and J1-1, the
circuit must NOT be open
(measure the resistive value of the
PTC).
- between wires J1-3 and J1-2, the
circuit must be OPEN.
Replace the door
interlock and
restart the
diagnostic cycle
to check for
further alarm
conditions.
Check/replace the wiring and
restart the diagnostic cycle to
check for further alarm
conditions.
Replace the circuit board and restart
the diagnostic cycle to check for
further alarm conditions.
fig. 9
Circuit
board
n
Ω
∞
Ω
J9
J10
J7
J2 J1
U3
Fig.4
If there are traces of
burning on the circuit
board, refer to page
59