2007-10 SOI/DT-mdm FCPD-dp Quality-fz
43/59
599 70 32-47
NO
YES
NO
NO
YES
NO
YES
YES
Tests to be performed:
E62: Overheating during washing
E62
The temperature of the NTC sensor exceeds 88°C for more than 5 minutes
E62
Circuit
board
Measure the NTC sensor
across terminals J9-9 and
J9-8 of the circuit board
connector.
Is the value correct?
(between 5.7 and 6.3 K
Ω
at
20°C)
Start the diagnostic cycle
and fill with water up to the
level of the door to ensure
that the heating element is
completely dipped into.
Measure between wiring
connector J2-2 and the
structure of the appliance
-
see fig 6 -
Is the circuit open?
Detach the connector and
measure across the heating
element and the ground
contact.
- see fig. 15 -
Is the circuit open?
Replace the heating
element and restart the
diagnostic cycle to check
for further alarm
conditions.
Check/replace the wiring and restart the diagnostic cycle to check
for further alarm conditions.
Detach the connector and
measure directly on the
NTC sensor.
- see fig. 14 -
Is the value correct?
(between 5.7 and 6.3 K
Ω
at
20°C)
Replace the NTC sensor
and restart the diagnostic
cycle to check for further
alarm conditions.
Replace the circuit board
and restart the diagnostic
cycle to check for further
alarm conditions.
Check/replace the wiring
and restart the diagnostic
cycle to check for further
alarm conditions.
If there are traces of burning
on the circuit board, refer to
page
59
fig. 15
fig. 6