34 www.electrolux.com
●
●
Disconnect the mains plug from the
mains socket.
WARNING!
Do not remove the filter while the
appliance is operating. Do not clean
the drain pump if the water in the
appliance is hot. The water must be
cold before you clean the drain pump.
To clean the drain pump:
1. Open the drain pump door.
2. Place a suitable water container
below the recess of the drain pump
to collect the water that flows out.
Press the two levers and pull forward
the drainage duct to let the water flow
out.
3. When the container is full of water,
put the drainage duct back again and
empty the container. Do step 2, 3
again and again until no more water
flows out from the drain pump.
4. Push back the drainage duct and
turn the filter counter-clockwise to
remove it.
Summary of Contents for EWF1141SEWA