CAUTION!
Put a cloth on the bottom of the
interior of the appliance. It pre-
vents damage to the lamp glass
cover and the cavity.
Always use the same lamp type.
Replacing the lamp at the cavity
ceiling:
1.
Turn the lamp glass cover counter-
clockwise to remove it.
2.
Clean the glass cover.
3.
Replace the lamp with a suitable 300
°C heat-resistant lamp.
4.
Install the glass cover.
12.
WHAT TO DO IF…
WARNING!
Refer to the Safety chapters.
Problem
Possible cause
Remedy
The appliance does not
heat up.
The appliance is deacti-
vated.
Activate the appliance.
The appliance does not
heat up.
The clock is not set.
Set the clock. Refer to
"Setting the clock".
The appliance does not
heat up.
The necessary settings
are not set.
Make sure that the set-
tings are correct.
The appliance does not
heat up.
The automatic cut-out is
activated.
Refer to “Automatic
switch-off”.
The appliance does not
heat up.
The fuse is released.
Make sure that the fuse is
the cause of the malfunc-
tion. If the fuse releases
again and again, contact
a qualified electrician.
The lamp does not oper-
ate.
The lamp is defective.
Replace the lamp.
The display shows an er-
ror code that is not on
this list.
There is an electrical fault. • Deactivate the appli-
ance with the house
fuse or the safety
switch in the fuse box
and activate it again.
• If the display shows the
error code again, con-
tact the Customer Care
Department.
If you cannot find a solution to the prob-
lem yourself, contact your dealer or the
service centre.
The necessary data for the service centre
is on the rating plate. The rating plate is
on the front frame of the appliance cavity.
We recommend that you write the data here:
Model (MOD.)
.........................................
Product number (PNC)
.........................................
32 www.electrolux.com