TSE-P 10.00 FV
24/38
599 34 41-93
CONVERSION FROM NATURAL TO LPG GAS
IMPORTANT
Replacement/conversion of the gas hob
shoud only be undertaken by a CORGI-
registered engineer.
It is important to note that this model is designed
for use with butane or propane gas providing the
correct injectors are fitted. The gas rate is
adjusted accordingly. The oven burner does not
require any primary air regulation.
REPLACEMENT OF GAS OVEN BURNER
NOZZLE
To replacement the gas oven nozzle, proceed as
follows:
a) remove the bottom of the oven;
b) remove screws “a” and “b” and take the oven
burner out;
c) using a 7mm socket wrench, unscrew and
remove the nozzle, situated in the bottom of
the oven,and replace it with the correct one
(see Table on this page);
d) reassemble the burner following the same
procedure in reverse sequence.
Fig. 29
CHARACTERISTICS OF BURNERS AND NOZZLES
TYPE OF GAS
NOZZLE
1/100 mm
NOMINAL
POWER
kW
POWER
IN
m3/h g/h
NOMINAL
GAS
PRESSURE
(mbar)
MIN.
PRESSURE
mbar
MAX
PRESSURE
mbar
NATURAL GAS
(G20)
114
2,7
257
-
20
17
25
BUTANE
(G30)
78
2,5
-
180
30
20
35
PROPANE
(G31)
78
2,7
-
180
37
25
45