A special valve for routinely turning the gas
supply on/off must be installed between the
gas inlet tube to the room and the hob, in
order to cut off the gas supply after cooking
in the event of accidents during cooking. This
valve must be easily accessible at all times,
and should be closed during long periods of
no use.
The gas tube must be routed in such a way
that it is not fed through hot areas and does
not come into contact with any hot parts of
the appliance, e.g. the underside of the hob.
Tube installation must be carried out in such
a way as to ensure that it runs freely and that
it cannot come into contact with or be bent
by any movable parts in the kitchen, e.g.
drawers.
If this is not the case, a special pressure
regulator must be fitted to the gas supply pipe
in accordance with the relevant standards.
The cooker must be connected to the gas
supply pipe such that the cooker is not
subjected to any kind of stress.
In order to guarantee that the cooker works
safely and has a moderate energy
consumption and long service life, you must
ensure that the supply pressure corresponds
to the values given in table D.
Gas Connection
Prior to installation, ensure that the local
distribution conditions (nature of the gas and
gas pressure) and the adjustment conditions
are compatible. The adjustment conditions
for this appliance are stated on the rating plate
which can be found on the back cover. This
appliance is not designed to be connected to
a combustion products evacuation device.
Particular attention should be given to the
relevant requirements regarding ventilation.
Connection to the cooker should be made
with connection in accordance with local
regulations.
For UK:
This appliance must be installed by a qualified
electrician / competent person
gas safe
register.
Safety may be impaired if installation
is not carried out in accordance with these
instructions.
The appliance must be installed in accordance
with All relevant British Standards (latest
editions).
Gas Safety (Installation & Use) Regulations
It is the law that all gas appliances are installed
by competent persons in accordance with the
current edition of the
Installation & Use
Regulations.
It is in your interest and that of
safety to ensure compliance with the law.
The cookers can be set for supply both on
the right or lefthand side (fig 12). In this case
it is sufficient to reverse the position of the
cad nipple reducer. At the end make sure
than there is no leakage of gas.
Warning: do not use flames to check any
gas leakages.
GB
1/2
Fig. 12
16
INLET
STOP