GB
IMPORTANT
The wires in the mains cable are coloured as
follows:
GREEN AND YELLOW .....EARTH
BLUE .................................NEUTRAL
BROWN.............................LIVE
REPLACING OF THE CABLE
If the cable becomes damaged or worn,
replace it, observing the following instructions:
- open the box of the supply board
(see fig. 16A);
- unscrew screw A that secures the cable;
- replace the cable with one of the same
length and which corresponds to the features
described in the table; switch the appliance
off, and shut the gas tap;
- connect the green-yellow earth wire to the
terminal , leaving it approximately 10
mm longer than the live wire;
- connect the blue neutral wire to the terminal
marked N;
- connect the live wire to the terminal marked
L.
This appliance must be installed by a
qualified person in accordance with the
latest IEE Regulations and in compliance
with the manufacturers instructions.
Check that the voltage is the same as that
stated on the rating plate. The rating plate is
located on the back cover.
WARNING! THIS APPLIANCE MUST BE
EARTHED
If a fixed appliance is not equipped with supply
cable and plug, the power supply must be
fitted with a disconnect switch in which the
distance between contacts permits total
disconnection in accordance with overvoltage
category III, as required by installation
regulations.
We recommend that the cooker circuit is rated
to 20 amps.
Cable type HO5 RRF 3 X 2.5 mm2
Connecting the mains cable (fig. 16A).
Open the mains terminal block cover as
shown, unscrew screw A the cable clamp,
and loosen the screws in the mains terminal
block L N E which secure the three wires of
the mains cable. Fit the cable and refit screw
A, the cable clamp.
Allow sufficient cable length for the cooker to
be pulled out for cleaning, but do not let it
hang lower than 50mm (2) from the floor.
The cable can be looped if necessary, but
make sure that it is not kinked or trapped
when the cooker is in position.
Fig. 16A