34
electrolux
connection to the gas system using
rigid pipes (ex. copper) or using flexible
stainless steel pipes, to avoid any stress
to the unit. Gas feeding pipe fitting is Gc
1/2. For this type of installation,
connection to the gas supply should be
carried out using only and exclusively
flexible metallic tubes in conformity with
rules in force.
Connection using flexible non
metal pipes
When the connection can be easily
inspected in its full extent, there is the
chance to use a flexible pipe according
to the rules in force. The flexible pipe
must be tightly fixed using clamps
according to the rules in force.
The flexible pipe should be made
ready for use in such a way that:
-
nowhere it can reach
overtemperature, other than room
temperature, higher than 30°C; if the
flexible pipe, to reach the cock, must
run behind the range, it must be
installed as shown in the diagram;
-
it is no longer than 1500 mm;
-
it shows no throttles;
-
it is not subject to traction or torsion;
-
it does not get in touch with cutting
edges or corners;
-
it can be easily inspected in order to
check its condition.
The control of preservation of the
flexible pipe consists in checking that:
-
it doesn't show cracks, cuts, marks
of burnings both on the end parts and
on its full extent;
-
the material is not hardened, but
shows its normal elasticity;
-
the fastening clamps are not rusted;
-
expiry term is not due.
If one or more abnormalities are seen,
do not repair the pipe, but replace it.
IMPORTANT
Once installation is complete, check
the perfect seal of every pipe fitting,
using a soapy solution, never a
flame.
Periodic checks
Have the gas connection pipe
checked periodically for signs of wear
and get it replaced immediately by a
qualified technician if it is found to be
faulty.
It is advisable to replace the pipe
before the service life expiry date, wich
is indicated on the pipe itself.
In the event of faulty operation, have
the cooker checked by a qualified
technician.