34
Maintenance and cleaning
Work light
The hood has two PL lamps 9 W.
Switch on and off with the left slide switch.
Correct ventilation
To have the cooker hood working correctly the
windows in the kitchen should be closed. In
stead a window in an adjacent room should be
open (Fig. 11).
Important to know
If the hood is run at the same time as a burner or
fireplace that depend on ambient air (for example
gas, Diesel, coal or wood heaters, water heaters,
etc.) be careful, because the hood, when it
exhausts the air, removes the ambient air re-
quired by the burner or fireplace for combustion.
Not valid if the cooker hood is used in
recirculation mode.
Before performing any maintenance
operation, disconnect the hood from
the electricity.
Grease filter
This serves to hold the grease particles in sus-
pension. The metal filter should be washed every
month with warm soapy water or, if possible, in
the dishwasher (60
°
C).
Remove the filter:
●
Open the latch A and rotate the grid down-
wards (Fig. 12).
●
To remove, pull forward from the right hand
side and unhook.
●
Release the clips F (Fig. 13).
Leave to dry before refitting it.
Grid must be cleaned as well as the grease filter.
Carbon filter
This filter dissolves cooking odours.
It should be changed every 6-8 months in normal
use. Ask the technical assistance service or
manufacturing company for a new one.
The carbon filter must never be washed.
To remove the carbon filter, push the hooks C
and pull the filter downwards (Fig. 9).
Fig. 11
A
Fig. 12
Fig. 13
F
Summary of Contents for EFT 629