12.1
If the drying results are not
satisfactory
• The set programme was incorrect.
• The filter is clogged.
• The Heat Exchanger is clogged.
• There was too much laundry in the
appliance.
• The drum is dirty.
• Incorrect setting of the conductivity
sensor ( See chapter "
Settings -
Adjustment of the remaining laundry
moisture degree
" for better setting).
• The airflow slots are clogged.
• Room temperature is too low or too
high ( optimal room temperature 19°C
to 24°C )
13.
TECHNICAL DATA
Height x Width x Depth
850 x 600 x 540 mm (maximum 600 mm)
Max. depth with the appliance door open 1030 mm
Max. width with the appliance door open
950 mm
Adjustable height
850 mm (+ 15 mm - feet regulation)
Drum volume
104 l
Maximum load volume
7
kg
Voltage
230-240 V
Frequency
50 Hz
Total power
2800 W
Type of use
Household
Permitted ambient temperature
+ 5°C to + 35°C
Level of protection against ingress of sol‐
id particles and moisture ensured by the
protective cover, except where the low
voltage equipment has no protection
against moisture
IPX4
www.electrolux.com
18
Summary of Contents for EDC704GEWA
Page 1: ...EDC704GEWA EN Tumble Dryer User Manual ...
Page 22: ...www electrolux com 22 ...
Page 23: ...ENGLISH 23 ...