erant located.
• Anti-static precautions in necessary for
installing air conditioner, e.g. wear pure
cotton clothes and gloves.
• Keep leak detector in working state during
the installation.
• If R290 refrigerant leakage occurs dur-
ing the installation, you shall immediately
detect the concentration in indoor environ-
ment until it reaches a safe level. If refriger-
ant leakage affects the performance of the
unit, please immediately stop the opera-
tion, and the unit must be vacuumed firstly
and be returned to the maintenance sta-
tion for processing
• Keep electric appliance, power switch,
plug, socket, high temperature heat source
and high static away from the area under-
neath sidelines of unit.
• The unit shall be installed in an accessible
location to installation and maintenance,
without obstacles that may block air inlets
or outlets of units, and shall keep away
from heat source, inflammable or explosive
conditions.
Requirements For Installation Position
• Avoid places of inflammable or explosive
gas leakage or where there are strongly
aggressive gases.
• Avoid places subject to strong artificial
electric/magnetic fields.
• Avoid places subject to noise and reso-
nance.
• Avoid severe natural conditions (e.g. heavy
lampblack, strong sandy wind, direct sun-
shine or high temperature heat sources).
• Avoid places within the reach of children
• Select where it is easy to perform service
and repair and where the ventilation good
Installation environment inspection
• Check nameplate of unit to make sure
whether the refrigerant is R290.
• Check the floor space of the room. The
space shall not be less than usable
space(i2m2) in the specification. The unit
shall be installed at a well-ventilated place.
• Check the surrounding environment of
installation site: R290 shall not be installed
in the enclosed reserved space of a build-
ing).
Installation
Guide of customer
• The customer should have a qualified
power supply coincident with that printed
on the tag of the air conditioner.
• Must use dedicated and efficient ground-
ing outlet matching with the plug of the air
conditioner.
• The appliance should be installed in accor-
dance with national wiring regulation
• The plug should be easily accessible after
installation.
Select a best location
More than 50cm
Mor
e
than
50cm
1. Install the mobile air conditioner in a flat
and spacious location where the air outlets
will not be obstructed.
2. A minimum clearance of 50cm from walls
or other obstacles should be kept.
3. The gradient can't be more than 10
degrees with the horizontal plane, while
placing and using the unit.
4. Uneven ground may cause additional
noise or vibration, or lead to damage to
the unit.
Note:
1. The air conditioner shall not be used in the
laundry.
2. The plug shall be accessible after the unit
is positioned.
Duct mount instruction
• In cooling, heating and drying mode, the
exhaust duct needs to be installed while in
fan mode, the exhaust duct is not needed.
• According to the actual needs, the exhaust
duct can be moderately compressed and
tensed, but cannot be arbitrarily stretched
and bent.
• The exhaust duct can be connected with
Windows or installed into the wall. With
the actual needs, you can make the
installation with accessories of the unit.
1. Install the adaptor A and adaptor B( flat
mouth or round mouth) onto the exhaust
duct as shown in Fig.Aor Fig.В.