Electrolux EACM-09 HR/N6 User Manual Download Page 6

6   

 button — Press this button, you can 

select the fan speed as follows: 

  auto—► hi —► med — low

  The fan speed indicator light illuminates 

under the different fan speed.

Note:

 In fan mode,do not have auto fan 

speed;
4- -   or -   button

a.  Each time the +   or -   button is 

pressed, the setting temperature will 

increase or decrease by 1 °С (IT). The 

setting temperature ranges from 16°C 

(60T)~32 °С (90 °F).

b.  By pressing both the +   and -   

button at the same time(>3s), the 

display will toggle between Celsius and 

Fahrenheit.

5. 

 button — Press this button, you can 

select the running mode as follows:

  auto —► cool —► dry—► fan—►heat  

Heat-pump type:

  auto—►cool—►dry—► fan

 

Cool only units:

The mode indicator light illuminates under the 

different mode.
6. 

 button — Press this button to enter sleep 

mode, which the unit will exit after 8 hours 

of continuous operation and restore to the 

previous status.

Note: 

The SLEEP function can not be activated 

in fan and dry mode.

7. 

 button

a.  Press the " " button, the timer indicator 

light illuminates.

b.  Press + ( ) or - ( ) button to select 

the desired time.

c.  After setting time 5 seconds without 

other operation, the timing function will 

be initiated automatically. If you press 

the timer button, there are no operation 

within 5 seconds or setting time is 0, 

the timing function will be cancelled 

automatically.

d.  When the timing function is initiated, the 

unit displays the remaining time by press 

the "timer" button once and cancel the 

timing function by press it again.

Note:

 With the unit on, press this button to set 

off timer.

With the unit off, press this button to set on 

timer.

8. 

 button —Press this button, the swing 

indicator light will illuminat

WARNING

  Failure to follow the below precaution 

could result in electrical shock, fire , 

explosion or personal injury.

1.  The plug must be plugged into an 

individual socket that is properly installed 

and grounded.

2.  Do not use an extension cord or plug 

adaptor with this unit.

Before starting the unit

1.  Select a suitable location, make sure the unit 

is near to an electrical outlet.

2.  Install the flexible exhaust hose and the 

adjustable window slider kit.

3.  Plug the unit into a right outlet.

Heating operation mode (Cool only unit has 

no heating function)

1.  Press the MODE button in a sequence until 

the heat indicator is lighted.

2.  Press the "+"and "-"button to setting your 

desired setting temperature.

3.  Press FAN button to select the fan speed.

Cooling operation mode

1.  Press the MODE button in a sequence until 

the cool indicator is lighted.

2.  Press the "+"and "-"button to set your 

desired setting temperature.

3.  Press FAN button to select the fan speed.

Drying operation mode

1.  Press the MODE button in a sequence until 

the dry indicator is lighted.

2.  The fan will run at a fixed speed at this 

operation mode.

3.  Close windows and doors for the best 

dehumidifying effect.

Note:

 The setting temperature and fan speed 

can not be adjusted.The setting temperature is 

25°C (77°F) and the fan speed is low. 

Fan operation mode

1.  Press MODE button in a sequence until the 

fan indicator is lighted.

2.  Press the FAN button to select the fan 

speed.

Note: The setting temperature can not be 

adjusted.

 

Auto-restart function:

If power to the unit is interrupted, the unit will 

restart itself in its last used mode / settings 

once power is restored. The compressor will 

restart after 4 minutes.

1.  Set: Press the sleep button 10 times within 5 

seconds, buzzer sounds 4 times.

2.  Cancel: Press the sleep button 10 times 

within 5 seconds, buzzer sounds 2 times. 

Summary of Contents for EACM-09 HR/N6

Page 1: ...USER S MANUAL EACM 09 HR N6 EACM 12 HR N6 ...

Page 2: ...able EACM 09 HR N6 EACM 12 HR N6 WE THINK ABOUT YOU Thank you for purchasing an Electrolux appliance You have chosen a product backed by decades of professional experience and innovations Unique and stylish it was created with care for you Therefore whenever you use it you can be sure that the results will always be excellent Welcome to Electrolux Content Safety information 3 Parts Description 4 C...

Page 3: ... may cause harm or damage to people properties etc The seriousness is classified by the following indications WARNING This symbol indicates the possibility of death or serious injury CAUTION This symbol indicates the possibility of injury or damage to properties WARNING This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabiliti...

Page 4: ...k fire or personal injury 1 The plug must be plugged into an outlet that is properly installed and grounded 2 Do not use an extension cord or plug adaptor with this unit CAUTION Don t apply the cold air to the body for a long time It will deteriorate your physical conditions and cause health problems Don t block air inlet or air outlet otherwise the cooling heating capacity will be weakened even c...

Page 5: ...rol Panel TEMP indicator TEMP indicator In cooling or heating mode when or button is pressed the setting temperature is displayed and be adjusted 1 In auto cool and heat mode TEMP indica tor display is setting temperature 2 In dry and fan mode TEMP indicator dis play is room temperature Function buttons 1 button Press this button to make the unit run or stop 2 button a The running time of the unit...

Page 6: ...G Failure to follow the below precaution could result in electrical shock fire explosion or personal injury 1 The plug must be plugged into an individual socket that is properly installed and grounded 2 Do not use an extension cord or plug adaptor with this unit Before starting the unit 1 Select a suitable location make sure the unit is near to an electrical outlet 2 Install the flexible exhaust h...

Page 7: ...se it 2 No automatic wind sweep function models air louver minimum opening angle from air louver closed state breaking up 5 grid air louver opening angle can not be less than the minimum open angle when use it Unpacking Inspection Open the box and check unit in area with good ventilation open the door and win dow and without ignition source Note Operators are required to wear anti static devices I...

Page 8: ...m The space shall not be less than usable space i2m2 in the specification The unit shall be installed at a well ventilated place Check the surrounding environment of installation site R290 shall not be installed in the enclosed reserved space of a build ing Installation Guide of customer The customer should have a qualified power supply coincident with that printed on the tag of the air conditione...

Page 9: ... Screw A window slide kit Wall exhaust adaptor Adaptor B round mouth 2 Attach the window slider kit to the window sash Adjust the length of the Window Slider Kit Loose the screw A to adjust the length of the Window Slider Kit then tight the screw when the length is suitable Note the length of the Window Slider Kit is 67 5cm to 120cm Screw B 3 Carefully lower the window Secure the vent panel in pla...

Page 10: ...efficiency As the following fig Shows Do not Yes Without installation If the unit does not have the window slider kit and wall exhaust and the Adaptor В is like this as shown in Fig H You can open the window slightly and position as shown in Fig I Fig H Fig I Water drainage During dehumidifying mode remove the upper drain plug from the back of the unit Attach the drain hose to the hole Place the o...

Page 11: ...ouring water directly over any of the surface areas as this will cause deterioration of electrical components and wiring insulation Clean the unit When the unit is contaminated clean it gently with a wrung towel using tepid water below 40 C 104 F Clean the Air Filter 1 Remove the air filter Take out the upper air filter and the lower air filter Note There are two types about the low air intake gri...

Page 12: ...itioner with R290 refrigerant and maintain the air conditioner in strictly accordance with manufacturer s requirements The chapter is mainly focused on special maintenance requirements for appliance with R290 refrigerant Ask repairer to read after sales technical service handbook for detailed information Qualification requirements of maintenance personnel 1 Special training additional to usual ref...

Page 13: ... correct specification At all times the manufacturer s maintenance and service guidelines shall be followed If in doubt consult the manufacturer s technical department for assistance The following checks shall be applied to installations using flammable refrigerants The charge size is in accordance with the room size within which the refrigerant con taining parts are installed The ventilation mach...

Page 14: ... to reach the working pressure under the vacuum state then the oxygen free nitrogen is emitted to the atmosphere and in the end vacuumize the system Repeat this process until all refrigerants in the system is cleared After the final charging of the anaerobic nitrogen discharge the gas into the atmosphere pres sure and then the system can be welded This operation is necessary for welding the pipeli...

Page 15: ... and they should be in a good condition If possible empty tanks should be evacu ated and maintained at room temperature before use 3 The recovery equipment should be kept in a good working condition and equipped with equipment operating instructions for easy access The equipment should be suitable for the recovery of R290 refriger ants Besides there should be a quali fied weighting apparatus which...

Page 16: ...ay be considered as expendable supplies or which are made of glass The warranty is void if the defect is caused by damage ensuing by misuse poor maintenance for example a failure occurred due to ingress of foreign objects or liquids or if changes or repairs were performed by persons not authorized by the Manufacturer For the correct use of the product the user must strictly follow all included in ...

Page 17: ...in technical and typing errors Changes to technical characteristics and assortment are subject to change without notice Mistakes and typing errors may be permitted in texts and numeric notations Product design and technical data may vary from the one pictured on the packaging Please refer to a sales consultant for more detailed information ...

Page 18: ......

Page 19: ...Seller Seal Date of sale Model Product Details populated upon sale Serial number ...

Page 20: ...via Estonia and CIS countries only Electrolux is a registered trademark used under license from AB Electrolux publ This manual may contain technical and typing errors Changes to technical characteristics and assortment are subject to change without notice ...

Reviews: