background image

5

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS

1.

If local codes permit connection of the frame
grounding conductor to the neutral (white) wire.

Connect the green (or bare copper) wire and the
white wire from the appliance cable to the supply
cable ground wire (white or bare) inside the junction
box. Connect the remaining wires inside the junction
box from the power supply cable to the matching
colors of the appliance cable wires (figure 4).

WARNING

Improper connection of aluminum

house wiring to copper leads can result in a short
circuit or fire. Use only connectors designed for
joining copper to aluminum, and follow the
manufacturer's recommended procedure closely.

 Frame grounded through the neutral.

If used in a mobile home, new branch circuit (1996
NEC) recreational vehicles or where local codes do
not permit grounding through neutral see figure 5.

2.

If used in mobile homes or if local codes DO
NOT permit connection of the frame grounding
conductor to the neutral (white) wire

, separate

the white and bare copper ground wires that extend
out of the end of the supply cable of the appliance.
Connect the white wire from supply cable to the
neutral white wire in the junction box. Connect the
black and red wires from the supply cable to the
matching color wires in the junction box. The bare
wire must now be used to ground the appliance in
accordance with local electrical codes. Connect the
bare copper ground wire to the grounded lead in the
service panel. DO NOT ground to a gas supply pipe.
DO NOT connect to electrical power supply until
appliance is permanently grounded. Connect the
ground wire before turning on the power (figure 5).

If connecting to a 4-wire electrical

system, the appliance frame MUST NOT be
connected to the neutral wire of the 4-wire
electrical system.

NOTE TO ELECTRICIAN:

 The armored cable leads

supplied with the appliance are CSA-recognized for
connection to larger gauge household wiring. The
insulation of the leads is rated at temperatures much
higher than temperature rating of household wiring. The
current carrying capacity of the conductor is governed by
the temperature rating of the insulation around the wire,
rather than the wire gauge alone.

Cooktop Installation

1. Visually inspect the cooktop for damage.
2. If you are installing the optional Stainless Steel

backsplash, first fix it at the back of the cooktop using
the screws supplied with the Kit and follow the
instructions attached.
Go to step 3, If you are not installing the Optional
Stainless Steel backsplash.

3. Set the cooktop into the countertop cutout.

NOTE:

 Do not use caulking compound; cooktop should

be removable for service when needed.

Checking Operation

Refer to the 

Use and Care Guide

 for operation.

CAUTION

 Do not touch cooktop glass or elements.

They may be hot enough to burn.

Model and Serial Number Location

The serial plate is located under the cooktop or in the burner
box and can be seen by lifting up the main top of unit.
When ordering parts for or making inquires about your
cooktop, always be sure to include the model and serial
numbers and a lot number or letter from the serial plate
on your cooktop.

Before You Call for Service

Read the Before You Call for Service Checklist and
operating instructions in your 

Use and Care Guide

. It

may save you time and expense. The list includes
common occurrences that are not the result of defective
workmanship or materials in this appliance.

Refer to your 

Use and Care Guide

 for Sears service

phone numbers. Please call if you have inquiries about
your product and/or need to order parts.

Figure 4

3-WIRE GROUNDED JUNCTION BOX

Cable from Power Supply

Black
Wires

Junction Box

U.L.-Listed Conduit
Connector (or CSA listed)

Cable from appliance

Ground Wire
(Bare or Green Wire)

Ground Wire

White Wire

R e d

Wires

Figure 5

4-WIRE GROUNDED JUNCTION BOX

Cable from Power Supply

White Wire

Junction Box

U.L.-Listed Conduit
Connector (or CSA listed)

Cable from appliance

Ground Wire
(Bare or Green Wire)

Ground Wire

White Wire

Black
Wires

R e d

Wires

Summary of Contents for E36EC75DSS

Page 1: ...head cabinetry is 30 76 2 cm WARNING Figure 1 P N 318201413 0403 Rev E English pages 1 5 Español pages 6 10 Français pages 11 16 A B C E F G H D Cooktop Dimensions 30 76 2 cm min for unprotected cabinet 24 61 cm min for protected surface Cooktop Cutout Dimensions 30 Min 76 2 cm For Standard Installation 35 1 8 89 2 cm 1 2 5 cm 4 X 8 10 2 cm x 20 3 cm opening to route armoured cable 7 18 4 cm Note ...

Page 2: ...to respect those dimensions D reflects a finished dimension it is recommended to undercut this dimension and adjust upon installation of the appliance due to the variation in countertop materials All dimensions are in inches cm Allow 2 5 cm space below the armoured cable opening to clear the electric cable and allow space for installation of the junction box on the wall at the back of the cooktop ...

Page 3: ...earance Between the Top of the Cooking Platform and the Bottom of an Unprotected Wood or Metal Cabinet 24 61 cm Min when Bottom of Wood or Metal Cabinet is Protected by Not Less Than 1 8 Flame Retardant Millboard Covered With Not Less Than No 28 MGS Sheet Steel 0 015 0 4 mm Stainless Steel 0 024 0 6 mm Aluminum or 0 020 0 5 mm Copper Approximate Location of Junction Box 18 45 7 cm It is not recomm...

Page 4: ...f the line time delay fuse or circuit breaker is recommended DO NOT fuse neutral The fuse size must not exceed the circuit rating of the appliance specified on the nameplate NOTE Wire sizes and connections must conform with the fuse size and rating of the appliance in accordance with the National Electrical Code ANSI NFPA No 70 latest edition or with CSA standard C22 1 Canadian Electrical Code Par...

Page 5: ...gauge household wiring The insulation of the leads is rated at temperatures much higher than temperature rating of household wiring The current carrying capacity of the conductor is governed by the temperature rating of the insulation around the wire rather than the wire gauge alone Cooktop Installation 1 Visually inspect the cooktop for damage 2 If you are installing the optional Stainless Steel ...

Page 6: ...as funcionan con una alimentación eléctrica con puesta a tierra de fase singular 3 o 4 alambres 240 208 voltios 60 hertz y sólo AC Favor de notar que la distancia mínima entre la superficie de la estufa y los gabinetes adyacentes y por encima son de 30 76 2 cm 30 76 2 cm mín para un gabinete desprotegido 24 61 cm mín para una superficie protegida Figura 1 Dimensiones del Recortado de la Estufa Dim...

Page 7: ...na dimensión terminada que se recomienda para socavar esta dimensión y ajustar en el momento de la instalación del aparato debido a la variación de los materiales de la cocina No deslizar dentro del hueco de la alacena Los tornillos que sobresalen de la parte inferior de la unidad pueden dañar el acabado inferior del frente Todas las dimensiones se dan en pulgadas cm Deje un espacio de 2 pulgadas ...

Page 8: ... superior no debe sobrepasar una profundidad máxima de 13 33 cm 24 61 cm min cuando la parte inferior del armario de madera o metal está rotegida por una placa cortafuego retardante de llama de no menos de 1 4 cubierta con una lámina de acero msg no inferior al No 28 de acero inoxidable de 0 015 aluminio de 0 024 o cobre de 0 020 30 76 2 cm min de espacio entre la parte superior del fogón y la par...

Page 9: ... eléctrico solamente se necesita corriente con frecuencia de 60 Hz AC y fase única de 120 240 o 120 208 voltios suministrada por cable de 3 o de 4 alambres en un circuito separado con fusibles en ambos lados de la línea se recomienda un fusible de tiempo retardado o un cortacircuitos NO ponga un fusible en el hilo neutro El tamaño del fusible no tiene que exceder la capacidad del circuito necesari...

Page 10: ...ductor está gobernada por la calificación de la temperatura del aislamiento alrededor del alambre en vez de solamente el calibre del alambre Instalación de la Tapa de Cocina 1 Inspeccione visualmente la tapa de la cocina para ver si está dañada 2 Si va a instalar el Panel Protector Opcional de Acero Inoxidable primero colóquelo en la parte posterior de la tapa de la cocina usando los tornillos pro...

Page 11: ...ntre la plaque de cuisson et les armoires adjacentes et en surplomb est de 30 76 2 cm Figure 1 A B C E F G H D Dimensions de découpage pour la plaque de cuisson 30 Min 76 2 cm Minimum de 30 76 2 cm pour armoire non protégée Minimum de 24 61 cm pour surface protégée Ouverture de 4 X 8 10 2cm x 20 3 cm pour le câble armé Dimensions de la plaque de cuisson Ne glissez pas l appareil dans le comptoir L...

Page 12: ... critiques pour une installation adéquate de la table de cuisson Assurez vous de respecter ces dimensions D reflète une dimension finale Étant donné la variation dans le matériel du comptoir il est recommandé de tailler un peu plus petit que cette dimension et l ajuster lors de l installation de l appareil 7 18 4 cm DIMENSIONS DE DÉCOUPAGE H PROFONDEUR MODÈLE A LONGUEUR B LARGEUR C PROFONDEUR LONG...

Page 13: ...cier inoxydable d un minimum de 0 015 0 4 mm d aluminium de 0 024 0 6 mm ou de cuivre de 0 020 0 5 mm Dégagement minimum de 30 76 2 cm entre le haut de la surface de cuisson et la base de l armoire en bois ou en métal non protégée L armoire supérieure ne doit pas excéder une profondeur maximale de 13 33 cm Emplacement approximatif de la boîte de jonction Minimum de K du rebord de la plaque de cuis...

Page 14: ...de jonction sous l armoire et installez un câble de 120 240 ou 120 208 Volts AC au panneau de distribution à la plaque de cuisson Ne branchez pas encore le câble au panneau de circuits Exigences électriques Observez tous les règlements et les codes locaux applicables 1 Un câble électrique à 4 fils de 120 240 ou 120 208 Volts monophasé 60 Hz CA est requis sur un circuit séparé muni d un fusible sur...

Page 15: ...alimentation de l appareil Raccordez le fil blanc du câble d alimentation de l appareil au fil blanc de la boîte de jonction Connectez les fils rouge et noir du câble d alimentation au fil de couleur correspondante dans la boîte de jonction Le fil dénudé doit être utilisé pour la mise à terre de l appareil en accord avec les normes électriques locales applicables Connectez le fil dénudé en cuivre ...

Page 16: ...cement du numéro de modèle et de série La plaque signalétique est située sous la plaque de cuisson ou dans le boîtier et est visible lorsque la plaque de cuisson est relevée Pour toute commande de pièces ou demande de renseignements au sujet de votre plaque de cuisson assurez vous de toujours inclure le numéro de modèle et de série ainsi que le numéro ou lettre de lot de la plaque signalétique de ...