ELECTRIC WALL OVEN INSTALLATION INSTRUCTIONS

Important Notes to the Installer

1.

Read all instructions contained in these installation
instructions before installing the wall oven.

2.

Remove all packing material from the oven
compartments before connecting the electrical supply
to the wall oven.

3.

Observe all governing codes and ordinances.

4.

Be sure to leave these instructions with the consumer.

5.

THIS OVEN IS NOT APPROVED FOR STACKABLE OR
SIDE-BY-SIDE INSTALLATION.

Important Note to the Consumer

Keep these instructions with your Owner's Guide for future
reference.

IMPORTANT SAFETY
INSTRUCTIONS

Be sure your wall oven is installed and grounded

properly by a qualified installer or service
technician.

This wall oven must be electrically grounded in

accordance with local codes or, in their absence,
with the National Electrical Code ANSI/NFPA
No.70- latest edition in United Sates, or with CSA
Standard C22.1, Canadian Electrical Code, Part 1, in
Canada.

  Stepping, leaning or sitting on the

door of this wall oven can result in serious injuries
and can also cause damage to the wall oven.

Never use your wall oven for warming or heating

the room. 

Prolonged use of the wall oven without

adequate ventilation can be dangerous.

  The electrical power to the oven must

be shut off while line connections are being made.
Failure to do so could result in serious injury or
death.

1. Carpentry

Refer to figure 1 for the dimensions applicable to your
appliance, and the space necessary to receive the oven.
The oven support surface may be solid plywood or
similar material, however the surface must be level from
side to side and from front to rear.

2. Electrical Requirements

This appliance must be supplied with the proper voltage
and frequency, and connected to an individual, properly
grounded branch circuit, protected by a circuit breaker or
fuse, having amperage as noted on the rating plate (the
rating plate is located on the oven frame).

Observe all governing codes and local ordinances

1.

A 3-wire or 4-wire single phase 120/240 or 120/208
Volt, 60 Hz AC only electrical supply  is required on
a separate circuit fused on both sides of the line
(time-delay fuse or circuit breaker is recommended).
DO NOT fuse neutral. The fuse size must not exceed
the circuit rating of the appliance specified on the
nameplate. Consideration must be given for a
combination built-in oven and cooktop refer to unit
serial plate of each.

NOTE:

 Wire sizes and connections must conform with

the fuse size and rating of the appliance in accordance
with the American National Electrical Code ANSI/NFPA
No. 70-latest edition, or with Canadian CSA Standard
C22.1, Canadian Electrical Code, Part 1, and local codes
and ordinances.

  An extension cord should not be used

with this appliance. Such use may result in a fire,
electrical shock, or other personal injury.

2.

These appliances should be connected to the fused
disconnect (or circuit breaker) box through flexible
armored or nonmetallic sheathed cable. The flexible
armored cable extending from the appliance should
be connected directly to the junction box. The
junction box should be located as shown in figure 1
and with as much slack as possible remaining in the
cable between the box and the appliance, so it can
be moved if servicing is ever necessary.

3.

A suitable strain relief must be provided to attach
the flexible armored cable to the junction box.

Electrical Shock Hazard

• Electrical ground is required on this appliance.
• Do not connect to the electrical supply until

appliance is permanently grounded.

• Disconnect power to the junction box before

making the electrical connection.

• This appliance must be connected to a

grounded, metallic, permanent wiring system,
or a grounding connector should be connected
to the grounding terminal or wire lead on the
appliance.

• Do not use a gas supply line for grounding the

appliance.

Failure to do any of the above could result in a

fire, personal injury or electrical shock.

 During cold temperature weather to

prevent damage to the oven control, wait at least three
(3) hours after receiving this built-in oven before
switching the power. This will prevent possible damage
to the built-in oven control at power on.

Summary of Contents for E30EW85ESS - Icon Designer Series Electric Double Oven

Page 1: ...t level the oven glides will tend to slide out when opening the door NOTE Allow at least 23 59 1 cm clearance for door depth when it is open NOTE Dimension G is critical to the proper Figure 1 P N 318201515 0410 Rev B English pages 1 6 Español páginas 7 13 Français pages 14 20 All dimensions are in inches cm Do not remove spacers on the side walls and or on the back of the built in oven These spac...

Page 2: ...3 wire or 4 wire single phase 120 240 or 120 208 Volt 60 Hz AC only electrical supply is required on a separate circuit fused on both sides of the line time delay fuse or circuit breaker is recommended DO NOT fuse neutral The fuse size must not exceed the circuit rating of the appliance specified on the nameplate Consideration must be given for a combination built in oven and cooktop refer to unit...

Page 3: ...d bare copper ground wires that extend out of the end of the supply cable of the appliance Connect the white wire from supply cable to the neutral white wire in the junction box Connect the black and red wires from the supply cable to the matching color wires in the junction box The bare wire must now be used to ground the appliance in accordance with local electrical codes Connect the bare copper...

Page 4: ...ed to the cabinet and the appliance to prevent tipping of the wall oven and injury to persons Mounting Brackets Installation Instructions 1 Unpack the wall oven and find the 2 mounting brackets and screws included in the literature package 2 Install the mounting bracket in the cabinet as shown on figure 4 Note To prevent damage to cabinet it is recommended to drill 1 16 0 16 cm dia pilot holes bef...

Page 5: ...ill run The convection fan will stop running when the oven door is opened IMPORTANT NOTE A fan inside the oven will turn on as soon as the oven is operated Model and Serial Number Location The serial plate is located inside the oven on the side trim When ordering parts for or making inquires about your oven always be sure to include the model and serial numbers and a lot number or letter from the ...

Page 6: ...6 ELECTRIC WALL OVEN INSTALLATION INSTRUCTIONS NOTES ...

Page 7: ... horno debe estar centrado para prevenir una concentración excesiva de calor que podría resultar en daños por el calor o un incendio LA INSTALACION Y EL SERVICIO DEBEN SER EFECTUADOS POR UN INSTALADOR CALIFICADO IMPORTANTE GUARDE ESTAS INSTRUCCIONES PARA USO DEL INSPECTOR LOCAL DE ELECTRICIDAD LEA Y GUARDE ESTAS INSTRUCCIONES PARA REFERENCIA FUTURA Figura 1 Espaciador Puerta Abierta vea la nota DI...

Page 8: ...artefacto debe ser suministrado con el voltaje y la frecuencia adecuados y conectado a un circuito individual correctamente puesto a tierra protegido por un cortacircuito o un fusible con el amperio anotado en la placa de calificación la placa se encuentra en el armazón del horno Cumpla con todos los códigos en vigor y todos los re glamentos locales 1 Para el suministro eléctrico solamente se nece...

Page 9: ...Standard C22 1 Part 1 en Canadá En este electrodomestico se necesita un cable de toma a tierra Este electrodoméstico viene equipado con un cable de conexión de cobre Si esto tuviera que conectarse a los cables de aluminio de una casa use solamente los conectores especiales aprobados para empalmes de cobre y aluminio de acuerdo con el Código Eléctrico Nacional y los reglamentos y códigos locales Es...

Page 10: ...desnudo Alambre blanco Alambres negros Alambres rojos Si está conectado a un sistema eléctrico de 4 alambres el armazón del electrodoméstico NO TIENE QUE estar conectado al alambre neutro del sistema eléctrico de 4 alambres NOTA AL ELECTRICISTA Los conductores de cable blindados provistos con este artefacto son aprobados por UL para la conexión al alambrado de casa de un calibre mayor El aislamien...

Page 11: ...Dimensiones del hueco 28 1 2 72 4 cm Min 29 73 7 cm Max Soportes de montaje 46 117 2 cm 51 129 5 cm Min 51 3 4 131 4 cm Max Vuelva a colocar los soportes de rejillas las rejillas y las puertas del horno Refiérase al Manual del Usuario para las instrucciones Para retirar el horno y llevarlo al servicio introduzca la herramienta que trae el electrodoméstico en el hoyo que se encuentra del lado later...

Page 12: ...n los dos elementos se encienden y apagan en forma alterna y se enciende el ventilador El ventilador de convección dejará de funcionar cuando se abre la puerta del horno durante el horneado o asado por convección NOTA IMPORTANTE Un ventilador dentro del horno se encenderá tan pronto como el horno empiece a funcionar Ubicación del número de modelo y de serie La placa de serie se encuentra dentro de...

Page 13: ...13 INSTRUCCIONES DE INSTALACIÓN PARA EL HORNO ELECTRICO DE PARED NOTAS ...

Page 14: ... sur les parois latérales et ou à l arrière du four Ces entretoises centrent le four dans l espace fourni Le four doit être centré pour prévenir une accumulation excessive de chaleur pouvant causer un feu ou des dommages NOTE 1 La Base doit pouvoir supporter 400 lbs 181 4 kg 2 Assurez vous que le fond du cabinet est bien à niveau et que la façade de l armoire est d équerre Si le cabinet n est pas ...

Page 15: ...e la plaque signalétique est située sur le châssis du four Observez tous les règlements et les codes locaux applicables 1 Un câble électrique à 3 ou 4 fils de 120 240 ou 120 208 Volt monophasé 60 Hz CA est requis sur un circuit séparé muni d un fusible sur chaque fil conducteur fusible temporisé ou disjoncteur recommandé NE RELIEZ pas de fusible au neutre La capacité du fusible ne doit pas excéder...

Page 16: ...Fils rouges Boîte de jonction Mise à la terre du châssis au neutre Si l appareil est utilisé dans une maison mobile un nouveau branchement 1996 NEC un véhicule récréatif ou si les codes locaux n autorisent pas la connexion du conducteur de mise à la terre du châssis au neutre référez vous à la figure 3 2 Si l appareil est utilisé dans une maison mobile ou si les codes locaux N AUTORISENT PAS une c...

Page 17: ...ut basculer quand les portes sont ouvertes Il faut le fixer à l armoire les supports de fixations fournis avec le four encastré pour prévenir le basculement du four et des blessures corporelles Instructions d installation des supports de fixation 1 Déballez le four encastré et récupérez les 2 supports et les vis de fixation compris dans l emballage contenant la littérature 2 Installez les supports...

Page 18: ...vant de l armoire voir figure 5 Tout en glissant l appareil vers l intérieur tirez le câble gainé à travers le trou du plancher de l armoire et vers la boîte de jonction 4 Poussez l appareil à l intérieur contre l armoire les supports de fixation situés sur le côté de l appareil se fixeront derrière ceux qui viennent d être installés au cabinet voir la figure 6 Remettre les supports de grilles gri...

Page 19: ...onvection les deux éléments cyclent et le ventilateur convection situé à l arrière tourne Le ventilateur convection arrête lorsque l on ouvre la porte du four REMARQUE IMPORTANTE Un ventilateur fonctionne dès que le four est mis en marche Emplacement du numéro de modèle et de série La plaque signalétique est située sur le côté intérieur de la moulure latérale Pour toute commande de pièces ou deman...

Page 20: ...20 INSTRUCTIONS D INSTALLATION POUR FOUR ENCASTRÉ ÉLECTRIQUE NOTES ...

Reviews: