5 - TROUBLESHOOTING
5.1 - THE HOB DOES NOT SWITCH ON
Check
Result/Display
Cause
Solution
Condition
More than 10Kohm
(correct resistance)
The thermal
switch for the
mains circuit
has been
tripped (no
current)
Power board faulty
Replace power
board
Measure the
resistance
across the BPL,
BPN and
EARTH 2
terminals on
the power
board (see
page 12)
Less than 10Kohm
(incorrect
resistance)
Check
connections on
terminal
jumpers
.
Terminal
jumpers
incorrectly
connected
Incorrect
connection
Connect
terminal
jumpers
correctly
Test the final
stages of the
power board
(see page 25)
Measurement of
final stages
incorrect
Power board faulty
Replace power
board.
The induction
zone does not
switch on (hob
switched off)
Incorrect mains
voltage to the
power board
Connect the
wiring correctly
Check for
mains voltage
to the power
board
One of the
connector wires
(pins 4 or 5 on the
board) is
disconnected
Terminal
jumpers correctly
connected
Wires correctly
connected on
power board
Check that the
connectors on
the wiring
between the
control board and
the power board
are correctly
fitted (BC02 –
BC4 or BC05 –
BC4).
Connection not
correct
False contacts on
connectors
Fit connectors
correctly
Connection correct