WARNING
warning
USE AN AUTHORISED PERSON
As stated in the local municipal building codes and other relevant
statutory regulations:
• Wiring connections must be in accordance with AS/NZS
3000 Wiring Rules and any particular conditions of the
local authority.
• Refer to data plate for rating information. The data plate is
positioned behind the bottom of the oven door.
• A means of disconnection with a contact separation of at least
3mm must be supplied in the fixed wiring.
• Wiring should be protected against mechanical failure.
Refer to AS/NZS 3000 clause 3.9
• To gain access to the mains connection terminals, remove
the rear panel by unscrewing the 2 assembly screws.
• This appliance must be connected with cable of 75°C
rating minimum.
• This product has passed the insulation resistance test after
manufacture. If the resistance reading is low at installation,
it is probably caused by moisture from the atmosphere
being absorbed by the elements after the appliance has
been produced. (pass at 0.01MΩ AS/NZS 3000 Wiring
Rules Clause 8.3.6.3).
NOTE: Where connection is made to a multi-phase 240V
supply, the bridge piece should be removed from between
the active connections.
Levelling oven
Place a level in the oven as below making sure the level sits on the
front and rear forms.
WARNING
warning
IMPORTANT: This appliance must be properly earthed.
• Do not lift the appliance by the door handles.
• Prepare the cupboard opening to match your appliance
measurements (See diagrams).
• Slide appliance into the cupboard, ensuring that the supply
cable (where fitted) does not kink.
• To prevent tipping, use the screws supplied to secure your
oven into the cupboard. Use just 2 screws for single cavity
ovens and 4 screws for dual cavity. Remove the bottom
door in dual cavity ovens to provide access to the bottom
2 screwing points (Refer to diagrams).
• For appliances fitted with a supply flexible cord, if the cord
is damaged, it must be replaced by the manufacturer or its
service agent or similarly qualified person in order to avoid
a hazard. The plug must be accessible after installation.
• Where the appliance is built into a cabinet, the cabinet
material must be capable of withstanding 70°C. Installation
into low temperature tolerant cabinetry (e.g. vinyl coated)
may result in deterioration of the low temperature coating
by discolouring or bubbling.
• If the appliance is installed adjacent to vinyl-wrapped surfaces,
use an installation kit available from the vinyl-wrap supplier.
• Electrolux Home Products cannot accept responsibility
for damage caused by installation into low temperature
tolerant cabinets.
• After installation, test and ensure that the appliance operates
correctly before handing it over to the customer.
WARNING
warning
CAUTION: To avoid any potential hazard, you must follow our
instructions below when you install your appliance. Failure to
install the appliance correctly could invalidate any warranty
or liability claims and lead to prosecution.
installation
✓
Built-in Cooking INSTALLATION 5
Summary of Contents for CVE602
Page 37: ...Built in Cooking NOTES 37 notes ...