It is dangerous to alter the speci

fi

 cations or attempt to modify this product in any way.

Technical Information
DIMENSIONS

                      

 

HEIGHT OF CANOPY:  

 

 

70 mm

                                          

 

HEIGHT OF CHIMNEY:  

(UPPER SECTION)   415 mm

                                          

 

 

 

 

(LOWER SECTION)   740 mm

                                          

 

WIDTH OF CANOPY : 

 

 

898 mm

                                          

 

DEPTH OF CANOPY:  

 

 

650 mm

ELECTRICAL SUPPLY: 

     

 

VOLTAGE:  

 

 

220-240 V 50Hz

                                          

 

POWER CONSUMPTION:  

 

 

285 W

                                          

 

FAN MOTOR:  

 

 

 

205 W

                                          

 

LAMPS :   (4 x 20 W) 

 

 

80 W

DOUBLE INSULATED DO NOT EARTH

Note: CE Marking certi

fi

 es that this appliance complies with the requirements 

laid down in EEC directive 89:336. (Electromagnetic compatibility) and subse-
quent modi

fi

 cations and Low Voltage directive 72/23/E.

ELECTRICAL CONNECTIONS

Electrical Requirements

Any permanent electrical installation must comply with 
the latest I.E.E. Regulations and local Electricity Board 
regulations. For your own safety this should be under-
taken by a quali

fi

 ed electrician e.g. your local Electricity 

Board, or a contractor who is on the roll of the National 
Inspection Council for Electrical Installation Contracting 
(NICEIC).

Electrical Connection

Before connecting to the mains supply ensure that the 
mains voltage corresponds to the voltage on the rating 
plate inside the cooker hood.

This appliance is 

fi

 tted with a 2 core mains cable and 

must be permanently connected to the electricity supply 
via a double-pole switch having 3mm minimum contact 
gap on each pole. A Switched Fuse Connection Unit to 
BS1363 Part 4, 

fi

 tted with a 3 Amp fuse, is a recom-

mended mains supply connection accessory to ensure 
compliance with the Safety Requirements applicable to 

fi

 xed wiring instructions.

This appliance conforms to BS 800: 1988 and EEC 
Directive No. 78 308 regarding suppression of ra dio and 
television interference.

The symbol 

 on the product or on its packaging indicates that this product may not be treated as household waste. Instead it shall be 

handed over to the applicable collection point for the recycling of electrical and electronic equipment. By ensuring this product is disposed of 
correctly, you will help prevent potential negative consequences for the environment and human health, which could otherwise be caused by 
inappropriate waste handling of this product. For more detailed information about recycling of this product, please contact your local city of

fi

 ce, 

your household waste disposal service or the shop where you purchased the product.

Summary of Contents for CHI 950

Page 1: ...INSTRUCTION BOOK FOR ELECTROLUX COOKER HOOD CHI 950 cod 436002578_03 060403 UK ...

Page 2: ......

Page 3: ... ownership please ensure you complete and return the guarantee card supplied with the appliance For the User Important Safety Information Your Appliance Operating Instructions Cooker Hood Controls To Operate Recirculation Extraction Maintenance and Cleaning External Cleaning Metal Grease Filters Charcoal Filters To Remove Replace Charcoal Filter Changing the Halogen Light Something Not Working Ser...

Page 4: ...otor has cooled significantly It is dangerous to alter the specifications or modify this product in any way When installed between adjoining wall cabinets the wall cabinets must not overhang the hob If the room where the hood is to be used contains a fuel burning appliance such as a central heating boiler then its flue must be of the room sealed or balanced flue type If other types of flue or appl...

Page 5: ...5 YOUR APPLIANCE ...

Page 6: ...r filter saturation alarm has been triggered and the filter has to be replaced the metal grease filters must also be washed The activated charcoal odour filter is triggered after 200 working hours Activation and Reset check the Maintenance paragraph To Operate Select the required fan speed and light if required Recirculation In the recirculation mode the contaminated air enters the cooker hood thr...

Page 7: ...the control panel Metal Grease Filters The filters are washable and must be cleaned when the Led S1 lights up or at least every 2 months of opera tion or more frequently for particularly heavy usage Remove the metal grease filters one at a time by Releasing the catches on the filters the filters can be removed The metal grease filters should be washed by hand in mild soapy water or in a dishwasher...

Page 8: ...enerated It must be replaced when led S1 flashes or at least every 4 months The alarm signal will only light up when the extractor motor is switched on To Remove Replace the Charcoal Filters Remove the metal grease filters Remove the saturated activated carbon filter by releasing the fixing hooks Fit the new filter by hooking it into its seating Replace the metal grease filters This appliance can ...

Page 9: ... char coal filter is still effective If set up for extraction check that the ducting and outlets are not blocked The safety cut out device has been tripped Tum off the hob and then wait for the device to reset In guarantee customers should ensure that the above checks have been made as the engineer will make a charge if the fault is not a mechanical or electrical breakdown If you require an engine...

Page 10: ...Costs incurred for calls to put right appliances improperly installed or calls to appliances outside the United Kingdom Appliances found to be in use within a commercial environment plus those which are the subject of rental agree ments Products of Electrolux manufacture which are not marked by Electrolux This guarantee is in addition to your statutory and legal rights ELECTROLUX EUROPEAN GUARANTE...

Page 11: ...upply ensure that the mains voltage corresponds to the voltage on the rating plate inside the cooker hood This appliance is fitted with a 2 core mains cable and must be permanently connected to the electricity supply via a double pole switch having 3mm minimum contact gap on each pole A Switched Fuse Connection Unit to BS1363 Part 4 fitted with a 3 Amp fuse is a recom mended mains supply connectio...

Page 12: ... incorrect installation of the cooker hood or if the hood is not installed in compliance with relevant regulations controlling this type of installation Unpacking Before unpacking the cooker hood position the carton with the arrows pointing upwards as illustrated on the carton The cooker hood is made up of the following com ponents Ref Q ty Product Components 1 1 Hood Body complete with Controls L...

Page 13: ...red when installed above a slot in electric cooker or 787mm 30 1 2 when installed above a slot in gas cooker When installed between adjoining wall cabinets the wall cabinets must not overhang the hob and the distance between the underside of the cabinet and the worktop must be 450mm If the height of the wall cabinet is less than 450mm a gap of 50mm must be maintained either side of the hob This co...

Page 14: ...screws of the following type crossing them and leaving 4 5 mm from the ceiling For concrete ceilings use the appropriate plugs for the screw size not provided For Cavity ceiling with inner space with wall thi ckness of approx 20 mm Screws not provided For wooden beam ceilings use 4 wood screws not provided For wooden shelf use 4 screws with washers and nuts not provided Fixing the Frame Loosen the...

Page 15: ...impaired The ducting used must be manufactured from fire retardent material conforming to the relevant British Standard or DIN 4102 B1 When the cooker hood is ducted to the outside the charcoal filter must be removed INSTALLING THE COOKER HOOD Before tightening the screws completely it is possible to adjust the frame by turning it Make sure that the screws do not come out of their seats in the slo...

Page 16: ...quate supply of air to the room The cooker ducting extraction mode must never be connected to central heating flues radiators or water heaters etc Recirculation The cooker hood is supplied specified for use in the recirculation mode with the charcoal filter fitted In the recirculation mode contaminated air is passed through the charcoal filter to be purified and recirculated into the kitchen throu...

Page 17: ...Before fixing the hood body to the frame Remove the grease filters from the hood body Remove any activated charcoal filters From below use the 4 screws 12f M6 x 10 Electrical Connection Being sure that the connector of the feeding cable is correctly inserted in the socket placed on the side of the fan Connect the control connector Cmd Connect the lights connector Lux Place the connectors in the ju...

Page 18: ...to the Service Force Centre covering your post code area Service and Spare Parts Before calling out an engineer please ensure you have read the details under the heading Something Not Working When you contact the Service Force Centre you will need to give the following details 1 Your name address and post code 2 Your telephone number 3 Clear and concise details of the fault 4 The model and serial ...

Page 19: ......

Page 20: ...AddingtonWay Luton BEDFORDSHIRE LU4 9QQ Electrolux plc 2002 ...

Reviews: