background image

15

Hood body mounting

•  Firstly, it is necessary to adjust the two 

Vr

-screws of 

the 

11a

-brackets, at minimun (

B

).

•  Hang the hood body on the two brackets 

11a

.

•  Connect the hood to the mains supply by means of 

a bipolar switch with at least 3 mm contact gap.

•  see Part 

USE

 to open the upper panel

•  Remove the metal filters by using the handles

•  In  order  to  align  the  hood  it  is  necessary  to  adjust 

the 

Vr

-screws from inside the hood.

•  Fasten the safety screw 

11

.

•  Fit  again  the  metal  filters  into  their  seats  and  see 

Part 

USE

 to close the upper panel.

•  Disconnect the hood from the mains supply.

 

 

Attention

: If any barrier occurs in its way during the 

panel opening or closing, the upper panel stops for 

1 sec and starts again the other way round. If within 

5  sec  the  panel  does  not  open  or  close,  the  motor 

stops. Press the key once again.

Chimney assembly

Upper exhaust Chimney

•  Slightly  widen  the  two  sides  of  the  upper  chimney 

and  hook  them  behind  the  brackets 

7.2.1

,  making 

sure that they are well seated.

•  Secure the sides to the brackets using the 4 screws 

12c

 (2,9 x 9,5) supplied.

Lower exhaust Chimney

•  Slightly  widen  the  two  sides  of  the  chimney  and 

hook them between the upper chimney and the wall, 

making sure that they are well seated.

•  Fix  the  lower  part  laterally  to  the  hood  body  using 

the 2 screws 

12c

 (2,9 x 9,5) supplied.

���

���

���

�����

���

INSTALLATION INSTRUCTIONS

� � �

���

��

��

Summary of Contents for AEG DD9996-B

Page 1: ...DD9996 B Cooker Hood Operating and Installation Instructions ...

Page 2: ...the Shelves Chimney assembly Top Shelf Electrical Connection and Working Test Guide to use the instruction book The following Symbols will be found in the text to guide you through the instruction book Safety instructions Step by step instructions Thank you for buying an AEG product To enable you to use your appliance effectively and safely please read this instruction book carefully before using ...

Page 3: ...f flue or appliances are fitted en sure that there is an adequate supply of air to the room When the hood is used in conjunction with appliances supplied with energy other than electricity the nega tive pressure in the room must not exceed 0 04mbar to prevent fumes being drawn back into the room by the hood The ducting system for this appliance must not be connected to any existing ventilation sys...

Page 4: ...4 YOUR APPLIANCE ...

Page 5: ...g this key it is possible to set the delayed shutdown of the motor and the lighting to 30 minutes A flashing clock symbol appears By pressing the key the function is deacti vated G By pressing this key for about 2 seconds it is possible to reset the filter saturation alarm A drop symbol indicates that the metal grease filters satu ration alarm has been activated and the filters need to be washed T...

Page 6: ...the relevant British Standard or DIN 4102 B1 When the cooker hood is ducted to the outside the charcoal filter must be removed When installing the ducted version connect the hood to the chimney using either a flexible or rigid pipe ø 150 or 125mm the choice of which is left to the installer To install a ø 150 Fix the pipe in position using sufficient pipe clamps not supplied To install a ø 120 To ...

Page 7: ...l Grease Filters Filters can be washed in the dish machine They need to be washed when Drop sign appears on the display or in any case every 2 months or even more frequently in case of particularly intensive use of the hood To Remove the Grease Filter Open the upper panel by pressing the A key for few second see Part USE Remove the filters one by one pushing them towards the back side of the hood ...

Page 8: ...ted during the instal lation or later Switch off the hood and the lights Press the E key for about 5 seconds until the last two segments of the motor LEDS are lit on the display By releasing the E key the clock icon starts to flash Within 3 seconds press the D key to activate deactivate charcoal filter saturation alarm C symbol lit charcoal filter saturation alarm ACTIVATED C symbol unlit charcoal...

Page 9: ...A by means of an appropriate tool to open the panel manually After having completely opened the panel remove the metal grease filters as explained in the partconcern ing the filter cleaning The fuser is placed up on the right side Turn the fuser holder as indicated Replace the fuser with one having the same features Open the panel by the control board see par USE button L so the moving arm comes o...

Page 10: ... for recirculation check that the charcoal filter is still effective If set up for extraction check that the ducting and outlets are not blocked The safety cut out device has been tripped Turn off the hob and then wait for the device to re set In guarantee customers should ensure that the above checks have been made as the engineer will make a charge if the fault is not a mechanical or electrical ...

Page 11: ...nt of any light bulbs or removable parts of glass or plastic Costs incurred for calls to put right appliances improperly installed or calls to appliances outside the United Kingdom Appliances found to be in use within a commercial environment plus those which are the subject of rental agreements Products of AEG manufacture which were not marketed by AEG This guarantee is in addition to your statut...

Page 12: ...ard regulations For your own safety this should be undertaken by a qualified electrician e g your local Electricity Board or a contractor who is on the roll of the National Inspection Council for Electrical Installation Contracting NICEIC Electrical Connection Before connecting to the mains supply ensure that the mains voltage corresponds to the voltage on the rating plate inside the cooker hood R...

Page 13: ...extraction ducted to the outside or recirculation internal recycling mode The Installation work must be undertaken by a qualified and competent person The manufacturer disclaims any responsibility to damages due to incorrect installation of the cooker hood or if the cooker hood is not installed in compliance with relevant regulations controlling this type of installation Unpacking Before unpacking...

Page 14: ... a reference point 3 at 743 mm above the cooker top on the vertical reference line Drill at the marked points 1 using a ø 12 mm drill bit Drill at the marked points 2 and 3 using a ø 8 mm drill bit Insert the bracket plugs 11a into the holes 1 and tighten the screws Insert plug 11 into holes 2 and 3 Place bracket 7 2 1 on the wall about 1 2 mm from the ceiling or from the upper limit aligning the ...

Page 15: ...mains supply Attention If any barrier occurs in its way during the panel opening or closing the upper panel stops for 1 sec and starts again the other way round If within 5 sec the panel does not open or close the motor stops Press the key once again Chimney assembly Upper exhaust Chimney Slightly widen the two sides of the upper chimney and hook them behind the brackets 7 2 1 making sure that the...

Page 16: ... the mains supply Open the upper panel by pressing the A key See Part USE for at least 2 seconds Remove the metal filters See Part MAINTENANCE and make sure that the connector piece of the supply cable is correctly inside the hood socket INSTALLATION INSTRUCTIONS ...

Page 17: ......

Page 18: ......

Page 19: ......

Page 20: ...al and electronic equipment By ensuring this product is disposed of correctly you will help prevent potential negative consequences for the environment and human health which could otherwise be caused by inappropriate waste handling of this product For more detailed information about recycling of this product please contact your local city office your household waste disposal service or the shop w...

Reviews: