![Electrolux AEG BS8304021M Service Manual Download Page 25](http://html.mh-extra.com/html/electrolux/aeg-bs8304021m/aeg-bs8304021m_service-manual_97421025.webp)
Technical Support - BSP
25/27
599 73 44-69
Rev. 00
F138
Oven temperature sensor is fixed on one
resitor value
Check Powerboard
Check temperature sensor
F140
Wrong configured cooking fan
Check software version and compare
with sparepart software
F142
Water level sensor (NTC) in steamer out of
range.
This Fault appears in case the steam generator
is overheated because the water refilling to the
system is prevented.
Check the Tubes are clogged
Check the Tubes assembly
Check the Descaling actuator is closed
Check the Inlet valve functioning
Check the Ambient temperature where
the appliance is placed ( it should not
be too low )
F143
Humidity sensor out of range
Check if sensor is powered on in
correct way
Check the Wiring
F191
Oven temperature sensor (PT500) out of range
(Warning)
Check wiring
Check temperature sensor
Check powerboard
F192
Foodprobe tmeperature value too high
Check wiring
Check foodprobe sensor and/or food
probe connection box
Check Foodprobe module
F193
Humidity sensor out of range warning
Check if sensor is powered on in
correct way
Check the Wiring
F194
Oven temperature sensor (PT500) out of range
(Warning)
Check wiring
Check temperature sensor
Check powerboard
F195
Electronic temperature value too high
Check Powerboard
F196
Electronic temperature value out of range
(warning)
Check Powerboard
F197
Water level sensor (NTC) in steamer out of
range.
Check the Tubes are clogged
Check the Tubes assembly
Check the Descaling actuator is closed
Check the Inlet valve functioning
Check the Ambient temperature where
the appliance is placed ( it should not
be too low )
F203
Programming not correct
Check software version and compare
the sparepart softwareCheck User
Interface
F208
F214
Configuration does not match to firmware of
user interface
Check software version and compare
with sparepart software
F215
Unexpected content of configuration
Check software version and compare
with sparepart software
Contact quality department
F233
F239
No communication between user interface and
Check User Interface