13.9 Solenoid valves
•
Remove the flexible water flow pipe making sure firstly that
you have closed the water low tap.
•
Remove the control panel.
•
Open the two clamps using a screwdriver, that block the pipes
carrying water from the solenoid valves to the water dispenser.
•
Disconnect the pipes that carry water from the solenoid valves
to the water dispenser.
•
Press the stop tabs with a screwdriver.
•
Rotate the whole solenoid valve unit until it has been
disconnected.
13.10 Air
break
•
With the help of a screwdriver, loosen the clamp locking the air
break inlet pipe in position, and remove the pipe.
•
Repeat the operation on the outlet pipe.
•
Release the pipe fastening clamp from its base.
•
Unfasten the pivots that fasten the air break to the structure.
•
Remove the filter pulling it upwards.