![Electrolux 60 cm Series Service Manual Download Page 44](http://html.mh-extra.com/html/electrolux/60-cm-series/60-cm-series_service-manual_91850044.webp)
TABLE OF ALARM CONDITIONS
The table below shows the meanings of the various Alarm Codes which may appear in the
DIGIT
window
and the possible causes of each.
ALARM CODE
TIME-OUT
POSSIBLE CAUSES
A
WATER FILL
Maximum duration 5 minutes
- Tap closed
- Mains water pressure too low
- Fill hose filter obstructed
- Solenoid valve inoperative
- Siphon effect in drain hose
- Intervention of anti-overflow device
- Intervention of anti-flooding device
- Control board faulty
C
SUPPLEMENTARY FILL
Maximum duration 45 seconds
(overall time)
- Leaks from sump or sump couplings
- Siphon effect in drain hose
- Circular filter obstructed
- Dishes upside-down
- Pressure switch faulty
- Leaks from pressure switch tube
- Control board faulty
F
PRESSURE SWITCH "EMPTY"
(waiting for temperature)
Maximum duration 2 minutes
not more than 3 times
- Leaks from sump or sump couplings
- Siphon effect in drain hose
- Circular filter obstructed
- Dishes upside-down
- Pressure switch faulty
- Leaks from pressure switch tube
- Control board faulty
L
TEMPERATURE SENSOR
Instantaneous intervention
during the heating phase
Operating range: -5° to 85°C
- Temperature sensor interrupted or out of range
- Connections loose/interrupted
- Temperature sensor incorrectly positioned
- Temperature sensor short-circuited
- Connections short-circuited
- Temperature in excess of 85°C
- Control board faulty
H
WATER HEATING
Maximum duration 45 minutes
excluding drying phase
- Heating element interrupted
- Connections interrupted
- Safety thermostat open
- Temperature sensor incorrectly calibrated or not in position
(poor contact)
- Circular filter obstructed
- Water level too low
- Upper spray arm jammed
- Control board faulty
P
PRESSURE SWITCH "EMPTY"
(end of drain)
Instantaneous intervention at the
end of each drain phase
- Drain pump inoperative
- Drain hose kinked
- Chamber drain siphon inoperative
- Recirculation hose obstructed or incorrectly positioned
- Pressure switch blocked on "full" (1 - 3)
- Control board faulty
- 44 -
Summary of Contents for 60 cm Series
Page 2: ... 2 ...
Page 8: ...STRUCTURE 8 ...
Page 9: ...INTERIOR OF TUB SUMP 9 ...
Page 10: ...HYDRAULIC ELECTRICAL COMPONENTS 10 ...
Page 15: ...WATER FILL CIRCUIT 15 ...
Page 17: ...LEVEL CONTROL CIRCUIT 17 ...
Page 19: ...WATER SOFTENING CIRCUIT 19 ...
Page 21: ...REGENERATION SYSTEM CIRCUIT DIAGRAM 21 ...
Page 28: ...FUNCTIONAL CIRCUIT DIAGRAM STANDARD TIMER 28 ...
Page 29: ...TIMER OPERATION STANDARD 29 ...
Page 30: ...FUNCTIONAL CIRCUIT DIAGRAM MEDIUM DE LUXE TIMER 30 ...
Page 31: ...TIMER OPERATION MEDIUM DE LUXE 31 ...
Page 34: ...FUNCTIONAL CIRCUIT DIAGRAM ITRONIC 34 ...
Page 35: ...CYCLE SEQUENCE ITRONIC 35 ...