![Electrolux 60 cm Series Service Manual Download Page 43](http://html.mh-extra.com/html/electrolux/60-cm-series/60-cm-series_service-manual_91850043.webp)
WATER HEATING
Time-out
- The maximum duration of the water heating phase
is 4
5 minutes
, irrespective of the temperature
for the selected cycle.
- The
time-out
counter starts at the beginning
of each water heating phase (i.e. when the
heating element switches on), and ends when
the correct temperature is reached.
- If the time required for the water to reach
the correct temperature is more than
45 minutes
,
an alarm condition is generated.
- During the final drying phase (after the last
hot rinse has been drained), this safety time-out
is no longer operative.
SITUATION
Appliance:
STOPPED
When the door is opened:
DIGIT
window:
H
(flashing)
LEDs:
OFF
PRESSURE SWITCH "EMPTY"
Time-out
(end of drain phase)
- At the end of each drain phase, it is checked
that the pressure switch is in the "empty"
condition (
1 - 2
).
- If the pressure switch is in the "full" condition
(
1 - 3
) at the end of the drain phase,
an alarm condition is generated.
SITUATION
Appliance:
STOPPED
When the door is opened:
DIGIT
window:
P
(flashing)
LEDs:
OFF
- 43 -
Summary of Contents for 60 cm Series
Page 2: ... 2 ...
Page 8: ...STRUCTURE 8 ...
Page 9: ...INTERIOR OF TUB SUMP 9 ...
Page 10: ...HYDRAULIC ELECTRICAL COMPONENTS 10 ...
Page 15: ...WATER FILL CIRCUIT 15 ...
Page 17: ...LEVEL CONTROL CIRCUIT 17 ...
Page 19: ...WATER SOFTENING CIRCUIT 19 ...
Page 21: ...REGENERATION SYSTEM CIRCUIT DIAGRAM 21 ...
Page 28: ...FUNCTIONAL CIRCUIT DIAGRAM STANDARD TIMER 28 ...
Page 29: ...TIMER OPERATION STANDARD 29 ...
Page 30: ...FUNCTIONAL CIRCUIT DIAGRAM MEDIUM DE LUXE TIMER 30 ...
Page 31: ...TIMER OPERATION MEDIUM DE LUXE 31 ...
Page 34: ...FUNCTIONAL CIRCUIT DIAGRAM ITRONIC 34 ...
Page 35: ...CYCLE SEQUENCE ITRONIC 35 ...