DOC. NO. 5958 9AY00
Edition 1 - 01.2013
121
GB - (category II2H3+)
Table 1 – General characteristics
Model / PNC
E9BSGIISFE / 391237
Z9BSGIISFE / 392237
A9BSGIISFE / 393237
E9BSGLIUFE / 391105
Z9BSGLIUFE / 392105
A9BSGLIUFE / 393105
Capacità of the tank:
to overflowing
litres
useful
litres
200
180
265
240
Capacità of the jacket:
min. level
litres
max. level
litres
total
litres
10
20
32
15
30
45
Jacket design pressure
kPa (bar)
50 (0,5)
50 (0,5)
Type of construction
A1
A1
Table 2 – Technical data
Model
E9BSGIISFE
Z9BSGIISFE
A9BSGIISFE
E9BSGLIUFE
Z9BSGLIUFE
A9BSGLIUFE
Inlet pressure of hot/cold water
kPa (bar)
100 – 250 (1 – 2,5)
100 – 250 (1 – 2,5)
Rated thermal power
kW
29
35
Minimum thermal power
kW
16
16,5
Gas consumption
(calculated with the lower heating value "Hi" at 15°C and 1013 mbar)
Natural gas G20 (Hi= 34,02MJ/m³)
m³/h
Liquid gas G30 (Hi= 45,65 MJ/kg
kg/h
Liquid gas G31 (Hi= 46,34 MJ/kg)
kg/h
3,07
2,29
2,25
3,70
2,76
2,71
Table 3 – Power supply
Single-phase supply voltage
VAC
220 - 230
Frequency
Hz
50 / 60
Power
kW
0,05
Power cord
3 x 1,5 mm²
Table 4 - Nozzles
MODEL E9BSGIISFE - Z9BSGIISFE - A9BSGIISFE
Type of gas
Nozzles of
main burner
Ø 1/100 mm
Nozzle of
pilot burner
N°
Nozzle of
ignition burner
Ø 1/100 mm
By-pass
Ø 1/100 mm
Air position of
main burner
H mm
Natural gas G20
2 x 300
1 x 27
1 x 105
1 x 235
23
Liquid gas G30
2 x 205
1 x 14
1 x 65
1 x 170
20
Liquid gas G31
2 x 205
1 x 14
1 x 65
1 x 170
20
Table 4 - Nozzles
MODEL E9BSGLIUFE - Z9BSGLIUFE - A9BSGLIUFE
Type of gas
Nozzles of
main burner
Ø 1/100 mm
Nozzle of
pilot burner
N°
Nozzle of
ignition burner
Ø 1/100 mm
By-pass
Ø 1/100 mm
Air position of
main burner
H mm
Natural gas G20
2 x 330
1 x 27
1 x 105
1 x 235
20
Liquid gas G30
2 x 220
1 x 14
1 x 65
1 x 170
25
Liquid gas G31
2 x 220
1 x 14
1 x 65
1 x 170
25
Table 5 – Gas connection
MODEL E9BSGIISFE - Z9BSGIISFE - A9BSGIISFE
Type of gas
Gas flow rate
kW
Nominal Reduced
Supply pressure
mbar
Nominal Minimum Maximum
Air for
combustion
m³/h
Natural gas G20
29
16
20
17
25
58
Liquid gas G30
29
16
30
20
35
58
Liquid gas G31
29
16
37
25
45
58
Table 5 – Gas connection
MODEL E9BSGLIUFE - Z9BSGLIUFE - A9BSGLIUFE
Type of gas
Gas flow rate
kW
Nominal Reduced
Supply pressure
mbar
Nominal Minimum Maximum
Air for
combustion
m³/h
Natural gas G20
35
16,5
20
17
25
70
Liquid gas G30
35
16,5
30
20
35
70
Liquid gas G31
35
16,5
37
25
45
70