Installation manual
55
Important
Tightness test after installation.
The gas leak test is performed as follows :
1. Paint pipe joints, pilot gas tubing connections and inspect outlets with rich soap and water solution ; do not
use an aggressive soap.
2. Put the machine into service. Bubbles indicate a gas leak.
3. Eliminate this leak.
Note!
After all intervention, re-seal (red varnish) the following adjustment organs:
— regulator of pressure.
In case of changing of gas, the stick for the adjustment has to be modified.
Important
Check-out
Before leaving, put the appliance into operation and allow to run a complete cycle.
Watch to ensure that all burner system components function correctly.
18.7 Control panel Gas exchanger :
Three indicators are situated on the top of the gas exchanger.
• White indicator (
H6
) light = “Gas heating on”
• Yellow indicator (
H5
) light = “ignition gas burner fault indicator”
• Red indicator (
H7
) light = “water fault in gas exchanger”
The yellow and red indicator remains on if a fault occurs when the gas burner ignites or if no water is detected inside
the gas exchanger, the gas heating does off and the machine stops functioning.
Verify the working of the gas exchanger.
If the fault remains, consult your after-sales service.
18.8 Electrical connection of gas exchanger to the washer machine
You have to connect the motor of extraction (D) to the gas exchanger
Summary of Contents for WH5-WHB5 500H
Page 2: ......
Page 26: ...26 Installation manual Back view Right view Drain connection Top view ...
Page 28: ...28 Installation manual Back view Right view Drain connection Top view ...
Page 40: ...40 Installation manual ...
Page 57: ...Installation manual 57 Connect cable W5 to gas boiler on connector X W5 ...
Page 66: ...66 Installation manual ...
Page 69: ......
Page 70: ...Electrolux Professional AB 341 80 Ljungby Sweden www electroluxprofessional com ...