Installation manual
43
Rep
Code
13
55015025
14
55015027
Replace the casings after taking care to remove the pre-cut of the right casing to allow the pass of the rubber hose.
15 Waters connections
Washer extractors are assembled in standard execution with two waters inlet.
One hot water and one hard water. On option, a third water inlet (soft) is possible.
The supply pipes to the machine should be fitted with manual shut-off valves to facilitate installation and service. Fit
filters to the manual shut-off valves with Teflon. Refer to local utilities regulations when fitting nonreturn valves. A
screen at the entrance to the machine filter should be necessarily mounted, it must have a mesh size of 0.3 mm
Any malfunction of water solenoid or water pneumatic valves due to a absence or a poor maintenance of the filters
will not be taken under warranty.
The following values apply to water pressure:
Water supply pressure, 50 kPa (7.25 psi) mini.
Water supply pressure, 300 kPa (43.5 psi) maxi.
Summary of Contents for WH5-WHB5 500H
Page 2: ......
Page 26: ...26 Installation manual Back view Right view Drain connection Top view ...
Page 28: ...28 Installation manual Back view Right view Drain connection Top view ...
Page 40: ...40 Installation manual ...
Page 57: ...Installation manual 57 Connect cable W5 to gas boiler on connector X W5 ...
Page 66: ...66 Installation manual ...
Page 69: ......
Page 70: ...Electrolux Professional AB 341 80 Ljungby Sweden www electroluxprofessional com ...