14
Gas oven with gas cookers (cont'd.)
Ecoflame
Connection ISO 7/1
Nominal heat output
Type exhaust flue
Ø
kW
A
M C Q J * * J C P O
1/2″
47
A1
M C Q N * * J C P O
●
1/2″
47
A1
M C Q I * * J C P O
1/2″
47
A1
M C Q M * * J C P O
●
1/2″
47
A1
C.4
How to interpret the factory description
The factory description on the data plate has the following
meaning:
1 - Product line
M
Modular
2 - Family (depth)
B
850 mm / 33,46″
C
900 mm / 35,43″
3 - Machine type + 4 - Zones
3
rd
4
th
V
G
French top with chimney on static gas oven
Q
I
4 zones burners on static gas oven
Q
J
4 zones burners on static gas oven passthrough
Q
M
4 zones burners Ecoflame on static gas oven
passthrough
Q
N
4 zones burners Ecoflame on static gas oven
5 - Module type (height)
E
700 mm / 27,56″, glass front panel
F
800 mm / 31,50″, glass front panel
G
700 mm / 27,56″, steel front panel
6 - User operating
A
One side
B
One side with back splash
C
Two sides
7 - Width
H
800 mm / 31,50″
J
1000 mm / 39,37″
8 - Base combination
C
Static oven gas
9 - Power supply
P
Gas (standard)
10 - Option
O
No options
C.5
Testing / Certification
All appliances are tested according to the relevant standards
and approved engineering rules by internationally recognised
testing bodies. This guarantees that all internationally required
quality and safety standards have been met.
All gas appliances meet the requirements set out in Regulation
(EU) 2016/426.
This appliance has passed the testing for protection class IPX4
(water protection).
To ensure continued compliance with this protection class, all
seals must remain in a perfect condition and all components
must be assembled properly after installation, repairs and
maintenance work.
D
GENERAL INFORMATION
D.1
Introduction
The drawings and diagrams given in the manual are not in
scale. They supplement the written information with an outline,
but are not intended to be a detailed representation of the
machine supplied.
The numerical values given on the machine installation
diagrams refer to measurements in millimeters and/or inches.
D.2
Intended use and restrictions
This appliance must not be used by minors and/or adults
with limited physical, sensory or mental abilities or with-
out adequate experience and knowledge regarding its use.
Children shall not play with the appliance. Cleaning and user
maintenance shall not be made by unauthorised personnel.
CAUTION
The machine is not suitable for installation
outdoors and/or in places exposed to
atmospheric agents (rain, direct sunlight,
etc.).
D.3
Copyright
This manual is intended solely for consultation by the operator
and can only be given to third parties with the permission of
Electrolux Professional company.
D.4
Keeping the manual
The manual must be carefully kept for the entire life of the
machine, until scrapping. The manual must stay with the
machine in case of transfer, sale, hire, granting of use or
leasing.
Electrolux Professional AG
Allmendstrasse 28
CH-6210 Sursee
PNC
:
Serial number
:
Type
:
Gas type
:
Gas supply pressure
:
Heat capacity
:
Hs
Gas rate
:
Construction
:
Manifold gas pressure
:
1
2 3 4 5 6 7 8 9 10
A
B C D E F G H I J