![Electrolux Professional IC43316 Operating Handbook Download Page 23](http://html.mh-extra.com/html/electrolux-professional/ic43316/ic43316_operating-handbook_2385589023.webp)
01103042
Page
Notice
Date
OPERATING
HANDBOOK
1004
5
2
5. Operating incidents
The heating does not
work, or works badly
Check the temperature preselection.
Check the safety thermostat.
Check to see if the panel is showing
overheating or a high temperature.
Gas heating
Check the gas inlet.
Clean pressure reducer filters.
Check electronic ignition.
Check the position of the ignition
electrodes and flame control.
Check operation of the gas solenoid
valve.
The flame is yellow
Check that the vapour intake fan is
working and is turning in the right
direction.
Check that air inlets are not blocked.
Check the combustion products
exhaust flue.
Check injector calibration.
Clean machine air inlet filters.
Electrical heating
Check heating contacts KM6, KM7
and KM8.
Check heating resistances.
Check the cylinder’s rotation
detection system.
Check the panel’s sensors.
Check resistance connections.
Check phases.
Encountered problem
Cause of problem
Solution