background image

8

9

REAR PANEL

Power amp output connection for the two channels A 
(left) and B (right) is provided via SPEAKON-type output 
connectors. 
A plastic cover to prevent inadvertent erroneous 
connection protects the BRIDGED OUT connector. Make 
sure to remove the cover only when actually operating 
the power amplifier in Bridged-Mode.

POWER AMP OUTPUT CONNECTORS 

BRIDGED MODE

 

 

 

  With the BRIDGED-MODE switch being engaged, using the channel A input 

 

 

 

  for audio signal feed is mandatory, since input B provides no function. While 

 

 

 

  the amplifier of channel A operates as usual, the audio signal is internally 

 

 

 

  inverted and routed to the amplifier of channel B. Both amps – A and B – now 

 

 

 

  work in push-pull operation to provide doubled output voltage at the 

 

 

 

  BRIDGED-OUT connector.

The regular output voltage of each amplifier channel A / B is still present at the 
corresponding output connector CHANNEL A or CHANNEL B. However, us-
ing these signals is not recommendable because of the aforementioned phase 
inversion. Operating the power amp in Bridged Mode with loads of 2ohms con-
nected is not allowable.

CAUTION: Extremely high voltages might be present at the BRIDGED OUT connector during 
Bridged-Mode operation. The connected loudspeaker systems have to be capable of handling 
such high voltages. Please make sure that power handling specifications as stated in the docu-
mentation supplied with your speaker systems match the specifications of the power amplifier.

GROUND-LIFT SWITCH

 

The ground-lift switch allows eliminating noise loops. If the power amplifier is 

 

operated together with other equipment in a 19“ rack-shelf, setting the switch 

 

to its GROUNDED position is recommended. If the power amplifier is operated

 

together with appliances with differing ground potentials, set the switch to its

 

UNGROUNDED position.

MAINS INPUT

 

Under normal circumstances, the mains fuse only blows in case of fault. 

                                         Replacing the fuse is only permissible when using a new fuse of the same 
                                         type with identical amperage, voltage and blow characteristics. If the mains 
                                         fuse blows more often, please contact an authorized service centre. 
 

The high-performance mains cord supplied with your power amplifier complies

                                         to applicable safety regulations, plus that its diameter corresponds to the pow-
er amp’s power output capacity. Make sure to use the supplied mains cord for connecting the power amp 
to the mains, if possible. Using mains cords with smaller diameters results in higher leakage and conse-
quently reduced maximum power output capacity.
At 100V and 120V units the mains fuse is installed internally. This is fore safety reasons. In case of a 
blown mains fuse please contact a qualified service personnel for servicing.

Summary of Contents for Precision CP 1200

Page 1: ...OWNER S MANUAL BEDIENUNGSANLEITUNG PRECISION SERIES CP 1200...

Page 2: ...UT 8 SPECIFICATIONS TECHNISCHE DATEN 20 BLOCK DIAGRAM 21 DIMENSIONS ABMESSUNGEN 22 WICHTIGE SICHERHEITSHINWEISE 13 WICHTIGE SERVICEHINWEISE 13 BESCHREIBUNG 14 AUSPACKEN GARANTIE 15 INSTALLATIONSHINWEI...

Page 3: ...cing other than that ontained in the Operating Instructions unless you are qualified to do so Refer all servicing to qualified service personnel 1 Security regulations as stated in the EN 60065 VDE 08...

Page 4: ...se The ventilation is directed front to rear allowing trouble free operation even in smaller amp racks The electronically balanced inputs are carried out via XLR type connectors female Direct Outs for...

Page 5: ...n easily rise up to 40 C during operation bearing in mind the maximally allowable environmental temperature during operation for all other appliances installed in the same rack shelf system is mandato...

Page 6: ...iters This indicator lights as soon as the integrated dynamic audio signal limiter is activated and the power amplifier is driven at the clipping limit or generally at its maximum capacity Short term...

Page 7: ...y s audio appliances employ balanced outputs With balanced cabling the shield connects all metal enclosure parts and therefore efficiently eliminates the introduction of external interference mostly n...

Page 8: ...handling such high voltages Please make sure that power handling specifications as stated in the docu mentation supplied with your speaker systems match the specifications of the power amplifier GROU...

Page 9: ...nt per hour CP 1200 Umains V Imains A Pmains W Pout W Pd 5 W BTU hr 1 idle 230V 0 37 42 42 143 Max Output Power 8 1 230V 4 6 743 2 x 240 263 895 Max Output Power 4 1 230V 7 5 1310 2 x 400 510 1740 1 3...

Page 10: ...10...

Page 11: ...BEDIENUNGSANLEITUNG PRECISION SERIES CP 1200...

Page 12: ...SPACKEN GARANTIE 15 INSTALLATIONSHINWEISE 15 FRONTSEITE 16 R CKSEITE 17 INPUT A INPUT B 17 PARALLEL 17 ENDSTUFENAUSG NGE 18 BRIDGED MODE 18 GROUND LIFT SCHALTER 18 NETZEINGANG 18 NETZBETRIEB W RMEENTW...

Page 13: ...t 11 Um das Ger t komplett spannungsfrei zu schalten muss der Netzstecker gezogen werden WICHTIGE SERVICEHINWEISE ACHTUNG Diese Servicehinweise sind ausschliesslich zur Verwendung durch qualifiziertes...

Page 14: ...r niedrigem Ger uschpegel gew hrleistet Die Front to Rear Luftf hrung erlaubt den Betrieb auch in gro en und schmalen Endstufen Racks Die Eing nge sind elektronisch symmetrisch auf XLR Buchsen gef hrt...

Page 15: ...temperatur der brigen im Gestellschrank befindlichen Ger te beachtet werden siehe auch Kapitel NETZBETRIEB UND W RMEENTWICKLUNG Achtung Die max Umgebungstemperatur von 40 C soll f r st rungsfreien Bet...

Page 16: ...auf sobald einer der eingebauten dynamische Audio Limiter anspricht und die Endstufe ber der Aussteuerungsgrenze oder generell im Grenz bereich betrieben wird Kurzzeitiges Aufleuchten ist dabei unpro...

Page 17: ...h aufgebaute Ausg nge Der Schirm im Kabel verbindet bei symmetrischer Signalf hrung alle metallischen Geh use und verhindert dadurch l cken los ein Einkoppeln von externen St rsignalen im wesentlichen...

Page 18: ...ossenen Lautsprecher m ssen f r derart hohe Spannungen ausgelegt sein Beachten Sie unbedingt die Leistungsangaben im Datenblatt des jeweiligen Lautsprechers und vergleichen Sie diese mit der entsprech...

Page 19: ...tunde CP1200 Umains V Imains A Pmains W Pout W Pd 5 W BTU hr 1 idle 230V 0 37 42 42 143 Max Output Power 8 1 230V 4 6 743 2 x 240 263 895 Max Output Power 4 1 230V 7 5 1310 2 x 400 510 1740 1 3 Max Ou...

Page 20: ...0Hz 7kHz 0 02 DIM30 3 15kHz 15kHz 0 01 Maximum Input Level 22dBu 9 76 Vrms Crosstalk ref 1kHz at rated output power 80dB Frequency Response ref 1kHz 15Hz 40kHz 1dB Input Impedance active balanced 20k...

Page 21: ...21 BLOCK DIAGRAM...

Page 22: ...22 ABMESSUNGEN...

Page 23: ...23 NOTES...

Page 24: ...nsville MN 55337 Phone 1 952 884 4051 FAX 1 952 884 0043 Germany EVI AUDIO GmbH Hirschberger Ring 45 D 94315 Straubing Germany Phone 49 9421 706 0 FAX 49 9421 706 265 Subject to change without prior n...