background image

20

21

SPECIFICATIONS

   - Amplifier at rated conditions, both channels driven, 8

 loads, unless otherwise specified.                      

- Depending on the ambient temperature, the unit might not operate continuously at 2

 load.

CP 1200

Load Impedance

2

4

8

Maximum Midband Output Power

THD = 1%, 1kHz, Dual Channel

600W

400W

240W

Rated Output Power 

THD < 0.1%, 20Hz ... 20kHz

--

300W

150W

Max. Single Channel Output Power

 

Dynamic-Headroom, IHF-A

1100W

580W

300W

Max. Single Channel Output Power

 

Continuous, 1kHz

800W

480W

270W

Max. Bridged Output Power

 

THD = 1%, 1kHz

--

1200W

800W

Maximum  RMS Voltage Swing 

THD = 1%, 1kHz

50V

Power Bandwith 

THD = 1%, ref. 1kHz, half power @ 4

10Hz ... 60kHz

Voltage Gain

ref. 1kHz

32,0 dB

Input Sensitivity

rated power @ 8

Ω 

, 1kHz

+1.15 dBu (0.88 V rms)

THD 

at rated output power, 

MBW = 80kHz, 1kHz

< 0.05%

IMD-SMPTE 

60Hz, 7kHz

< 0.02%

DIM30

3.15kHz, 15kHz

< 0.01%

Maximum Input Level

+22dBu (9.76 Vrms)

Crosstalk 

ref. 1kHz, at rated output power

< - 80dB

Frequency Response 

ref. 1kHz

15Hz ... 40kHz ( 

±

1dB)

Input Impedance

active balanced

20k

Damping Factor 

1kHz

>  300  

Slew Rate

25 V/

m

s  

Signal to Noise Ratio, Amplifier

A-weighted

103.5 dB

Output Noise

A-weighted

< -70 dBu

Output Stage Topology

Class AB

Power Requirements

240, 230, 220, 120V or 100V; 50Hz ... 60 Hz (factory configured)

Power Consumption

1/8 maximum output power @ 4

Ω, 

+10%

600W

Protection

Audio limiters, High temperature, DC, HF, Back-EMF,

Peak current limiters, Inrush current limiters, Turn-on delay

Cooling

Front-to rear, 3-stage-fans

Ambient Temperature Limits

+5°C ... +40°C   ( 40°F ... 105°F)

Safety Class

I

Dimensions

(W x H x D), mm

483 x 88,1 x 386,8

Weight

13.5 kg (30.8 Ibs)

Optional:

Rear-rackmount 15,5“

Rear-rackmount 18“

2-Way Crossover

, internal filter-card, 24dB, LR

(NRS 90262) 112930

 (NRS 90264) 112933

330Hz (NRS 90249), 500Hz (NRS 90250)

800Hz (NRS 90251), 1200Hz (NRS 90252)

Summary of Contents for Precision CP 1200

Page 1: ...OWNER S MANUAL BEDIENUNGSANLEITUNG PRECISION SERIES CP 1200...

Page 2: ...UT 8 SPECIFICATIONS TECHNISCHE DATEN 20 BLOCK DIAGRAM 21 DIMENSIONS ABMESSUNGEN 22 WICHTIGE SICHERHEITSHINWEISE 13 WICHTIGE SERVICEHINWEISE 13 BESCHREIBUNG 14 AUSPACKEN GARANTIE 15 INSTALLATIONSHINWEI...

Page 3: ...cing other than that ontained in the Operating Instructions unless you are qualified to do so Refer all servicing to qualified service personnel 1 Security regulations as stated in the EN 60065 VDE 08...

Page 4: ...se The ventilation is directed front to rear allowing trouble free operation even in smaller amp racks The electronically balanced inputs are carried out via XLR type connectors female Direct Outs for...

Page 5: ...n easily rise up to 40 C during operation bearing in mind the maximally allowable environmental temperature during operation for all other appliances installed in the same rack shelf system is mandato...

Page 6: ...iters This indicator lights as soon as the integrated dynamic audio signal limiter is activated and the power amplifier is driven at the clipping limit or generally at its maximum capacity Short term...

Page 7: ...y s audio appliances employ balanced outputs With balanced cabling the shield connects all metal enclosure parts and therefore efficiently eliminates the introduction of external interference mostly n...

Page 8: ...handling such high voltages Please make sure that power handling specifications as stated in the docu mentation supplied with your speaker systems match the specifications of the power amplifier GROU...

Page 9: ...nt per hour CP 1200 Umains V Imains A Pmains W Pout W Pd 5 W BTU hr 1 idle 230V 0 37 42 42 143 Max Output Power 8 1 230V 4 6 743 2 x 240 263 895 Max Output Power 4 1 230V 7 5 1310 2 x 400 510 1740 1 3...

Page 10: ...10...

Page 11: ...BEDIENUNGSANLEITUNG PRECISION SERIES CP 1200...

Page 12: ...SPACKEN GARANTIE 15 INSTALLATIONSHINWEISE 15 FRONTSEITE 16 R CKSEITE 17 INPUT A INPUT B 17 PARALLEL 17 ENDSTUFENAUSG NGE 18 BRIDGED MODE 18 GROUND LIFT SCHALTER 18 NETZEINGANG 18 NETZBETRIEB W RMEENTW...

Page 13: ...t 11 Um das Ger t komplett spannungsfrei zu schalten muss der Netzstecker gezogen werden WICHTIGE SERVICEHINWEISE ACHTUNG Diese Servicehinweise sind ausschliesslich zur Verwendung durch qualifiziertes...

Page 14: ...r niedrigem Ger uschpegel gew hrleistet Die Front to Rear Luftf hrung erlaubt den Betrieb auch in gro en und schmalen Endstufen Racks Die Eing nge sind elektronisch symmetrisch auf XLR Buchsen gef hrt...

Page 15: ...temperatur der brigen im Gestellschrank befindlichen Ger te beachtet werden siehe auch Kapitel NETZBETRIEB UND W RMEENTWICKLUNG Achtung Die max Umgebungstemperatur von 40 C soll f r st rungsfreien Bet...

Page 16: ...auf sobald einer der eingebauten dynamische Audio Limiter anspricht und die Endstufe ber der Aussteuerungsgrenze oder generell im Grenz bereich betrieben wird Kurzzeitiges Aufleuchten ist dabei unpro...

Page 17: ...h aufgebaute Ausg nge Der Schirm im Kabel verbindet bei symmetrischer Signalf hrung alle metallischen Geh use und verhindert dadurch l cken los ein Einkoppeln von externen St rsignalen im wesentlichen...

Page 18: ...ossenen Lautsprecher m ssen f r derart hohe Spannungen ausgelegt sein Beachten Sie unbedingt die Leistungsangaben im Datenblatt des jeweiligen Lautsprechers und vergleichen Sie diese mit der entsprech...

Page 19: ...tunde CP1200 Umains V Imains A Pmains W Pout W Pd 5 W BTU hr 1 idle 230V 0 37 42 42 143 Max Output Power 8 1 230V 4 6 743 2 x 240 263 895 Max Output Power 4 1 230V 7 5 1310 2 x 400 510 1740 1 3 Max Ou...

Page 20: ...0Hz 7kHz 0 02 DIM30 3 15kHz 15kHz 0 01 Maximum Input Level 22dBu 9 76 Vrms Crosstalk ref 1kHz at rated output power 80dB Frequency Response ref 1kHz 15Hz 40kHz 1dB Input Impedance active balanced 20k...

Page 21: ...21 BLOCK DIAGRAM...

Page 22: ...22 ABMESSUNGEN...

Page 23: ...23 NOTES...

Page 24: ...nsville MN 55337 Phone 1 952 884 4051 FAX 1 952 884 0043 Germany EVI AUDIO GmbH Hirschberger Ring 45 D 94315 Straubing Germany Phone 49 9421 706 0 FAX 49 9421 706 265 Subject to change without prior n...