background image

4

5

UNPACKING & WARRANTY

Carefully open the packaging and take out the power amplifier. Next to the power amplifier itself, the 
package also includes this owner’s manual, a mains cord and the warranty certificate. Keep the original 
invoice, which states the purchase/delivery date together with the warranty certificate at a safe place.

INSTALLATION NOTES

Generally, installing or mounting power amps should be carried out in a way that guarantees continu-
ously unopposed front-to-rear air circulation. Installation of appliances with opposite air circulation within 
one cabinet or closed rack shelf system is not recommended. When including an appliance in a closed 
cabinet or rack shelf system make sure to provide sufficient ventilation. Leave a gap of at least 

60mm 

x 330mm

 (up to the cabinet’s top ventilation louvers) for air circulation between the rear of the power 

amplifier and the cabinet’s/rack’s rear inner wall. Make sure to leave at least 100mm of space above the 
cabinet or rack shelf system. Since temperatures inside of the cabinet or rack shelf system can easily 
rise up to 40°C during operation, bearing in mind the maximally allowable environmental temperature 
during operation for all other appliances installed in the same rack shelf system is mandatory (also refer 
to “MAINS OPERATION AND RESULTING TEMPERATURE”). 

Caution:  For trouble-free operation exceeding the maximally allowable environmental temper-

ature of +40°C is not permissible.

The use of installation rails or optionally available “rear-rack-mount” rails is strongly recommended when 
installing the appliance in a rack shelf system or cabinet to prevent the front panel from bending.

The power amplifier has to be protected against: dripping or splashing water, direct sunlight, high tem-
peratures or direct influence of heat sources, high humidity, extensive dust and vibrations.
Condensation on internal parts may occur when transporting the power amplifier from a cold into a 
warmer environment. In that case operation is only permissible after the appliance has gained the 
new temperature (after approximately one hour). If foreign objects or liquids have entered the power 
amplifier’s enclosure make sure to instantly separate the appliance from the mains power and contact 
an authorised service centre for inspection before continuing operation.

DESCRIPTION

Summary of Contents for Precision CP 1200

Page 1: ...OWNER S MANUAL BEDIENUNGSANLEITUNG PRECISION SERIES CP 1200...

Page 2: ...UT 8 SPECIFICATIONS TECHNISCHE DATEN 20 BLOCK DIAGRAM 21 DIMENSIONS ABMESSUNGEN 22 WICHTIGE SICHERHEITSHINWEISE 13 WICHTIGE SERVICEHINWEISE 13 BESCHREIBUNG 14 AUSPACKEN GARANTIE 15 INSTALLATIONSHINWEI...

Page 3: ...cing other than that ontained in the Operating Instructions unless you are qualified to do so Refer all servicing to qualified service personnel 1 Security regulations as stated in the EN 60065 VDE 08...

Page 4: ...se The ventilation is directed front to rear allowing trouble free operation even in smaller amp racks The electronically balanced inputs are carried out via XLR type connectors female Direct Outs for...

Page 5: ...n easily rise up to 40 C during operation bearing in mind the maximally allowable environmental temperature during operation for all other appliances installed in the same rack shelf system is mandato...

Page 6: ...iters This indicator lights as soon as the integrated dynamic audio signal limiter is activated and the power amplifier is driven at the clipping limit or generally at its maximum capacity Short term...

Page 7: ...y s audio appliances employ balanced outputs With balanced cabling the shield connects all metal enclosure parts and therefore efficiently eliminates the introduction of external interference mostly n...

Page 8: ...handling such high voltages Please make sure that power handling specifications as stated in the docu mentation supplied with your speaker systems match the specifications of the power amplifier GROU...

Page 9: ...nt per hour CP 1200 Umains V Imains A Pmains W Pout W Pd 5 W BTU hr 1 idle 230V 0 37 42 42 143 Max Output Power 8 1 230V 4 6 743 2 x 240 263 895 Max Output Power 4 1 230V 7 5 1310 2 x 400 510 1740 1 3...

Page 10: ...10...

Page 11: ...BEDIENUNGSANLEITUNG PRECISION SERIES CP 1200...

Page 12: ...SPACKEN GARANTIE 15 INSTALLATIONSHINWEISE 15 FRONTSEITE 16 R CKSEITE 17 INPUT A INPUT B 17 PARALLEL 17 ENDSTUFENAUSG NGE 18 BRIDGED MODE 18 GROUND LIFT SCHALTER 18 NETZEINGANG 18 NETZBETRIEB W RMEENTW...

Page 13: ...t 11 Um das Ger t komplett spannungsfrei zu schalten muss der Netzstecker gezogen werden WICHTIGE SERVICEHINWEISE ACHTUNG Diese Servicehinweise sind ausschliesslich zur Verwendung durch qualifiziertes...

Page 14: ...r niedrigem Ger uschpegel gew hrleistet Die Front to Rear Luftf hrung erlaubt den Betrieb auch in gro en und schmalen Endstufen Racks Die Eing nge sind elektronisch symmetrisch auf XLR Buchsen gef hrt...

Page 15: ...temperatur der brigen im Gestellschrank befindlichen Ger te beachtet werden siehe auch Kapitel NETZBETRIEB UND W RMEENTWICKLUNG Achtung Die max Umgebungstemperatur von 40 C soll f r st rungsfreien Bet...

Page 16: ...auf sobald einer der eingebauten dynamische Audio Limiter anspricht und die Endstufe ber der Aussteuerungsgrenze oder generell im Grenz bereich betrieben wird Kurzzeitiges Aufleuchten ist dabei unpro...

Page 17: ...h aufgebaute Ausg nge Der Schirm im Kabel verbindet bei symmetrischer Signalf hrung alle metallischen Geh use und verhindert dadurch l cken los ein Einkoppeln von externen St rsignalen im wesentlichen...

Page 18: ...ossenen Lautsprecher m ssen f r derart hohe Spannungen ausgelegt sein Beachten Sie unbedingt die Leistungsangaben im Datenblatt des jeweiligen Lautsprechers und vergleichen Sie diese mit der entsprech...

Page 19: ...tunde CP1200 Umains V Imains A Pmains W Pout W Pd 5 W BTU hr 1 idle 230V 0 37 42 42 143 Max Output Power 8 1 230V 4 6 743 2 x 240 263 895 Max Output Power 4 1 230V 7 5 1310 2 x 400 510 1740 1 3 Max Ou...

Page 20: ...0Hz 7kHz 0 02 DIM30 3 15kHz 15kHz 0 01 Maximum Input Level 22dBu 9 76 Vrms Crosstalk ref 1kHz at rated output power 80dB Frequency Response ref 1kHz 15Hz 40kHz 1dB Input Impedance active balanced 20k...

Page 21: ...21 BLOCK DIAGRAM...

Page 22: ...22 ABMESSUNGEN...

Page 23: ...23 NOTES...

Page 24: ...nsville MN 55337 Phone 1 952 884 4051 FAX 1 952 884 0043 Germany EVI AUDIO GmbH Hirschberger Ring 45 D 94315 Straubing Germany Phone 49 9421 706 0 FAX 49 9421 706 265 Subject to change without prior n...