Troubleshooting Guide

Problem

Possible Solution

Unit Dead

Check for proper supply at 

terminals 2 and 10. See figure 5 on 

page 3

No Analog out with zero 

hertz displayed

Check for Sensor supply. It should 

be Approximately 13.6 VDC

Check sensor Gap distance
Check Sensor Type (Variable 2)

Unit displays a 

frequency but the analog 

is incorrect

Check variable 1 for correct 

frequency

Check your on the correct 

analog output, voltage(VDC) or 

current(mA)

Analog is unstable

Check gap distance

SA420 General Specifications:

Input Power

Input Current

Fuse Type (F2)

115 Vac, 60Hz (std)

2.5 VA

Sloblo .032A 5X20

230 Vac, 60Hz (opt)

2.5 VA

Sloblo .032A 5X20

12 Vdc (opt)

165 mA

Sloblo .250A 5X20

24 Vdc (opt)

135 mA

Sloblo .200A 5X20

Input Signal

Parameters

Sensor Supply

12 VDC (unregulated) @50 mA max.

Programmable Types

Open collector NPN / PNP

Logic Level 5 V Nom. 3 V Min.

Magnetic /- 75 MV Min.

Max. Amplitude 

25 Vpk-pk Maximum

Frequency Range

0.01 Hz to 10 kHz

Minimum Input for 

Full Scale Output

0.5 Hz = 3.8 RPM @ 8 PPR

(Lower full scale range is available, 

consult Factory)

Analog Output Signal

Parameters

Types

0 - 10 VDC, 4 - 20 mA with 500

Ω 

load max.

Accuracy (typical)

0.1% Linearity for both outputs

Step Response Time

Parameters

50 Hz Input and above

10 to 90% = 50 ms.

Below 50 Hz Input

10 to 90% = 30 ms + 1/Hz Input 

frequency

Physical/Envlronment

Parameters

Mounting

DIN rail mount or Stand alone

Operating temperature

0°C to +60°Cz

Storage temperature

-65°C to +125°C

Electrical Connections

11 Position DIN rail terminal 

block

DIN rail enclosure rating

NEMA 1

Free Catalog and Application Assistance

1.800.328.6170

Website: www.electro-sensors.com

990-001700 Revision I

8-8

255 Pulser Disc (std.)

Parameters **

Material

Nylon 12 Std, 

(opt; PVC, Alum, Stainless-Steel)

Dimensions

4-inch diameter x 1/4-inch thick

Operating Temperature

-40ºC to +60ºC* (Nylon, PVC)

Operating Temperature

-40ºC to +150ºC* (Alum, SS)

Pulser Wrap (optional) Parameters **

Material

PVC Std.

(opt; Aluminum or Stainless-Steel)

Operating Temperature

-40ºC to +60ºC* (PVC)

Operating Temperature

-40ºC to +150ºC* (Aluminum, SS)

 906 Sensor (Standard) Parameters **

Material Sensor Body

Aluminum 3/4 - 16UNF thread

Material Mount Bracket Plate steel
Output Types

NPN open collector current sinking 

20 mA max

Signal Cable

3-conductor shielded, 10 feet length 

std. (50 ft. or 100 ft. optional)

Operating Temperature

-40ºC to + 60ºC*

Air Gap

1/4 inch +/- 1/8 inch with standard 

255 Pulser disc (1/2” magnets)

907 Explosionproof 

Sensor (optional)

Parameters **

Class I, Div 1, Group D

Class II, Div 1, Groups E, F, G

UL File: E249019

Mounting Bracket 

Material

Plate Steel U-Bolt Assembly

Other Specifications

Similar to 906 standard sensor

Specifications are subject to change without notice.

*For higher or lower temperature ranges, consult factory.

** For details on Discs, Wraps and Sensors, consult factory 

or visit our website.

Summary of Contents for SA420

Page 1: ...o achieve the proper gap distance adjust the jam nuts holding the standard sensor in the mounting bracket or adjust the position of the explosion proof sensor using the slots on its mounting bracket P...

Page 2: ...wing units PR 04 Hz default Percent of maximum output User defined units Programmable minimum frequency cutoff PR 05 This allows you to decide where the unit zeroes out for faster zeroing More modes o...

Page 3: ...the calibration mode Programming The Unit Standard menu To enter the calibration mode push the ENT button once PR0 will be displayed Press the up button to increment to the desired variable Press the...

Page 4: ...o slew from 10 90 analog output PR 07 Signal Type Programming of PR 07 determines the way the signals are handled There are multiple choices for both single and quadrature operation 1X uses the rising...

Page 5: ...is approximately 366nA 0 000366uA of deviation up or down per single count of change Example of changing this from 1000 to 980 results in the analog decreasing It will decrease 20 0 000366uA or 0 007...

Page 6: ...0 0 5 VDC 1 0 10 VDC 2 5 VDC 3 10 VDC No 09 MENU_OPTION_VAR 1 0 1 0 Basic menu 1 Advanced menu Standard No 10 DISPLAY_OPTION_VAR 0 0 2 0 Hz 1 Percent output 2 User units No 11 reserved for future use...

Page 7: ...Disc 2 00 2 51 2 00 2 00 1 25 1 00 1 00 1 120 Figure 9 Standard Sensor 2 38 5 53 1 16 3 38 1 00 1 NPT 1 63 3 75 1 88 Nut Lockwasher 0 56 1 25 4 63 Figure 10 Explosionproof Sensor 1 00 43 0 13 2 75 1...

Page 8: ...hysical Envlronment Parameters Mounting DIN rail mount or Stand alone Operating temperature 0 C to 60 Cz Storage temperature 65 C to 125 C Electrical Connections 11 Position DIN rail terminal block DI...

Reviews: