Electro-Sensors SA420 Quick Start Manual Download Page 6

SA420 Advanced Mode Variables

Variable Number and Name

Default

Value

Value

Range

Coded Number Table

Move 

Decimal

User Values

(00) ANALOG_LOWER_SP_VAR

0

any number *

Yes

(01) ANALOG_UPPER_SP_VAR

240.0

any number *

Yes

(02) SENSOR_TYPE_VAR

0000

0-5

0 = NPN (2.5 VDC trip level)

1 = PNP (2.5 VDC trip level)  

2 = Mag (75 mVDC trip level)

3 = Logic (2.5 VDC trip level)

4 = NPN (6 VDC trip level)**

5 = PNP (6 VDC trip level)**

No

(03) BUFFER_SIZE_VAR

8

0-16

 

No

(04) USER_UNITS_VAR

1800

any number *

Yes

(05) FREQUENCY_CUTOFF_VAR

0.5

0.0-10.0 Hz

No

(06) ANALOG_RESPONSE_VAR

00.00

00.00-20.00

Amount of time it takes the analog 

output to change from 10% to 90%

Examples:

00.00 or 00.01 = 00.01 seconds 

00.10 = 0.10 seconds

00.50 = 00.50 seconds

No

(07) SIGNAL_TYPE_VAR    

0

0-4

0 = Single channel operation

1 = Quadrature operation

2 = Single channel 2X operation

3 = Quadrature operation 2X

4 = Quadrature operation 4X

No

(08) VOLTAGE_OUTPUT_TYPE VAR

1

0-3

0 = 0-5 VDC

1 = 0-10 VDC

2 = +/- 5 VDC

3 = +/- 10 VDC

No

(09) MENU_OPTION_VAR

1

0-1

0 = Basic menu

1 = Advanced menu (Standard)

No

(10) DISPLAY_OPTION_VAR 

0

0-2

0 = Hz

1 = Percent output

2 = User units

No

(11) reserved for future use

(12) reserved for future use

(13) reserved for future use

(14) reserved for future use

No

(15) SECUR_PIN_VAR 

0420

0000-9999

No

(16) SECUR_PASS_VAR

0420

0000-9999

No

(17) SECUR_CAL_PIN_VAR

0

0000-9999

No

(18) SECUR_CAL_PASS_VAR

0420

0000-9999

No

(19) CAL: VOLTAGE_OFFSET

1000

0000-2000

Currently not active

No

(20) CAL: VOLTAGE_GAIN

1000

0000-2000

Currently not active

No

(21) CAL: CURRENT_OFFSET

1000

0000-2000

No

(22) CAL: CURRENT_GAIN

1000

0000-2000

No

* When the ‘rate’ icon is flashing, the number being programmed is a reverse direction value. A value can only be displayed as a reverse direction 

value AFTER the unit is programmed to operate in quadrature mode. This prevents errant reverse values from being entered into a single-channel 

unit.

** Recommended quadrature setting for NPN or PNP. 

Free Catalog and Application Assistance

1.800.328.6170

Website: www.electro-sensors.com

990-001700 Revision I

6-8

Summary of Contents for SA420

Page 1: ...o achieve the proper gap distance adjust the jam nuts holding the standard sensor in the mounting bracket or adjust the position of the explosion proof sensor using the slots on its mounting bracket P...

Page 2: ...wing units PR 04 Hz default Percent of maximum output User defined units Programmable minimum frequency cutoff PR 05 This allows you to decide where the unit zeroes out for faster zeroing More modes o...

Page 3: ...the calibration mode Programming The Unit Standard menu To enter the calibration mode push the ENT button once PR0 will be displayed Press the up button to increment to the desired variable Press the...

Page 4: ...o slew from 10 90 analog output PR 07 Signal Type Programming of PR 07 determines the way the signals are handled There are multiple choices for both single and quadrature operation 1X uses the rising...

Page 5: ...is approximately 366nA 0 000366uA of deviation up or down per single count of change Example of changing this from 1000 to 980 results in the analog decreasing It will decrease 20 0 000366uA or 0 007...

Page 6: ...0 0 5 VDC 1 0 10 VDC 2 5 VDC 3 10 VDC No 09 MENU_OPTION_VAR 1 0 1 0 Basic menu 1 Advanced menu Standard No 10 DISPLAY_OPTION_VAR 0 0 2 0 Hz 1 Percent output 2 User units No 11 reserved for future use...

Page 7: ...Disc 2 00 2 51 2 00 2 00 1 25 1 00 1 00 1 120 Figure 9 Standard Sensor 2 38 5 53 1 16 3 38 1 00 1 NPT 1 63 3 75 1 88 Nut Lockwasher 0 56 1 25 4 63 Figure 10 Explosionproof Sensor 1 00 43 0 13 2 75 1...

Page 8: ...hysical Envlronment Parameters Mounting DIN rail mount or Stand alone Operating temperature 0 C to 60 Cz Storage temperature 65 C to 125 C Electrical Connections 11 Position DIN rail terminal block DI...

Reviews: